Duplex Ultrasound Volumetric Flow Analysis before and after Hemodialysis in Patients with Brachio-cephalic Fistulae

Author:

Chowdhury Shakila1,Goss David1,Mistry Hiren2,Stephenson Matthew A.2,Seed Paul3,Deane Colin1,Valenti Domenico2

Affiliation:

1. Vascular Laboratory, Kings College Hospital, London - UK

2. Department of Vascular Surgery, Kings College Hospital, London - UK

3. Kings College, London - UK

Abstract

Purpose The United Kingdom Renal Association recommends duplex ultrasound to monitor arteriovenous fistula (AVF) flow rates during surveillance. Significant flow rate changes should prompt further investigation or treatment to avoid a failing fistula. Hemodialysis is known to alter the hemorrheologic and physiologic factors with a potential impact on measured flow rates. The aim of this study was to determine the difference in flow rate measured with duplex ultrasound before and after a single hemodialysis session in patients with brachial-cephalic fistulae. Methods Patients with brachial-cephalic AVFs in our dialysis populations who were undergoing regular hemodialysis without recent intervention (less than six weeks) were invited to participate. Flow measurements were made pre-and post-hemodialysis using a Zonare ultrasound machine. The vascular scientist was always blinded to the pre-hemodialysis flow. Results A total of 157 patients were identified with brachial-cephalic fistulae. Following exclusions, 119 patients were eligible. However, a further 58 were excluded because they declined or did not attend leaving 61 patients in the study. Paired t test showed a statistically significant reduction in flow rate of 105 mL/min (P=0.026) post-hemodialysis which equates to a −6.9% change in flow (95% C.I. −12.7 to −0.8%). Bland-Altman analysis showed limits of flow rate agreement between −599 mL/min and +810 mL/min (+/-1.96 s.d.). Conclusions Whilst we have shown a statistically significant change in flow rate post-hemodialysis, this is small and should be taken in the context of previously accepted interobserver variability. Therefore, the practical and financial considerations of implementing an AVF surveillance programme are likely to outweigh the minimal benefit of consistency that would be enabled by strict protocol of pre-hemodialysis flow measurements.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3