Excellent inter-observer agreement between radiologist and nurse: tracheal carina-based identification of peripherally inserted central catheter tip position

Author:

Zhang Xiaoxia1,Jia Dan2,Ke Nengwen3,Liu Chang4,Fu Lan1,Hu Xiuying5

Affiliation:

1. Tumor Center, West China Hospital, Sichuan University, Chengdu, Sichuan Province - PR China

2. Department of General Medicine, West China Hospital, Sichuan University, Chengdu, Sichuan Province - PR China

3. Department of Pancreatic Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan Province - PR China

4. Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan Province - PR China

5. West China Nursing School, Sichuan University, Chengdu, Sichuan Province - PR China

Abstract

Introduction: Accurate identification of position of a central venous catheter tip is important to reduce catheter-related complications. Nevertheless, inter-observer bias limits the accuracy of traditional method for determining tip position on chest x-ray (CXR) images. The aim of this study was to explore a simple and objective method for assessing position of peripherally inserted central catheter (PICC) tip on CXR image. Methods: Tracheal carina was used as the landmark to identify positions of catheter tips. The central vein (CV) was located between 3 cm above and 4 cm below tracheal carina. The vertical distance from catheter tips to tracheal carina was measured independently by a nurse and re-assessed by a radiologist. Inter-observer agreement was expressed as percentage in agreement and kappa coefficient. Results: Six hundred and twelve CXR images of catheters taken from 612 patients were included. The inter-observer agreement between nurse and radiologist was 97.88% (kappa = 0.934) for all catheter tips evaluated, and 98.40% (kappa = 0.923) for catheter tips with regard to CV, innominate vein, and right atrium. Most discrepancies (9/13) between observers occurred when catheter tips were positioned in a border region between different anatomical parts. Conclusions: Inter-observer agreement between nurse and radiologist is excellent. Our results demonstrate that the measurement of distance between catheter tip and tracheal carina performed by a nurse provide a convenient and reliable way to determine position of PICC tip. Our study also suggests that nurses can be trained to handle PICCs, especially when properly located catheters are applied in critically ill patients during emergency setting.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3