Securement Methods for Peripheral Venous Catheters to Prevent Failure: A Randomised Controlled Pilot Trial

Author:

Marsh Nicole12,Webster Joan13,Flynn Julie12,Mihala Gabor24,Hewer Barbara1,Fraser John45,Rickard Claire M.125

Affiliation:

1. Centre for Clinical Nursing, Royal Brisbane and Women's Hospital, Herston - Australia

2. NHMRC Centre for Research Excellence in Nursing, Centre for Health Practice Innovation, Griffith Health Institute, Griffith University, Brisbane - Australia

3. School of Nursing and Midwifery, University of Queensland, Brisbane - Australia

4. School of Medicine, Griffith Health Institute, Griffith University, Meadowbrook- Australia

5. Critical Care Research Group, Adult Intensive Care Services, The Prince Charles Hospital and University of Queensland, Queensland - Australia

Abstract

Purpose To assess the effectiveness of four securement methods to prevent peripheral intravenous catheter (PIVC) failure. Methods A single-centre, four-arm, randomised, controlled, non-blinded, superiority pilot trial was conducted in a tertiary referral hospital in Queensland (Australia), between November 2012 and January 2013. Adult patients, with a PIVC expected to remain in situ for ≥24 hours and admitted to general medical or surgical wards, were randomly allocated to standard polyurethane dressing (control, SPU), tissue adhesive (TA) with an SPU, bordered polyurethane dressing (BPU) or sutureless securement device (SSD) with an SPU, experimental groups. The primary endpoint was PIVC failure, defined as premature device removal before the end of therapy because of pain, blockage, leaking, accidental removal and local or catheter-related bloodstream infection. Results PIVCs were used for an average of 2.6 days across all study groups (n = 85). Catheter failure was lowest in the TA group (3/21, 14%) and highest in the control group (8/21, 38%), with BPU and SSD failure at 5/20 (25%) and 5/23 (22%), respectively. The adjusted hazard ratio of catheter failure was lowest in the TA group (0.50, 95% CI: 0.13-1.98), and then the BPU (0.52, 95% CI: 0.15-1.78) and SSD (0.61, 95% CI: 0.20-1.91) groups. No patient was suspected of a local or catheter-related bloodstream infection. Conclusions Current SPU dressings alone do not prevent many cases of PIVC failure. TA appears promising as an innovative solution, but may not be suitable for all patients. A larger Australian National Health and Medical Research Council (NHMRC)-funded trial has commenced.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3