Novel Modular Anastomotic Valve Device for Hemodialysis Vascular Access: Preliminary Computational Hemodynamic Assessment

Author:

McNally Andrew1,Akingba A. George234,Robinson Eric A.2,Sucosky Philippe1

Affiliation:

1. Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana - USA

2. Department of Medicine, Division of Cardiology, Indiana University School of Medicine, Indianapolis, Indiana - USA

3. Department of Surgery, Division of Vascular Surgery, Indiana University School of Medicine, Indianapolis, Indiana - USA

4. Department of Biomedical Engineering, Indiana University Purdue University, Indianapolis, Indiana - USA

Abstract

Purpose Arteriovenous graft patency is limited by terminal occlusion caused by intimal hyperplasia (IH). Motivated by evidence that flow disturbances promote IH progression, a modular anastomotic valve device (MAVD) was designed to isolate the graft from the circulation between dialysis periods (closed position) and enable vascular access during dialysis (open position). The objective of this study was to perform a preliminary computational assessment of the device ability to normalize venous flow between dialysis periods and potentially limit IH development and thrombogenesis. Methods Computational fluid dynamics simulations were performed to compare flow and wall shear stress (WSS) in a native vein and MAVD prototypes featuring anastomotic angles of 90° and 30°. Low WSS (LWSS) regions prone to IH development were characterized in terms of temporal shear magnitude (TSM), oscillatory shear index (OSI), and relative residence time (RRT). Thrombogenic potential was assessed by investigating the loading history of fluid particles traveling through the device. Results The closed MAVD exhibited the same flow characteristics as the native vein (0.3% difference in pressure drop, 3.5% difference in surface-averaged WSS). The open MAVD generated five LWSS regions (TSM <0.5 Pa) exhibiting different degrees of flow reversal (surface-averaged OSI: 0.03–0.36) and stagnation (max RRT: 2.50–37.16). Reduction in anastomotic angle resulted in the suppression of three LWSS regions and overall reductions in flow reversal (surface-averaged OSI <0.21) and stagnation (max RRT <18.05). Conclusions This study suggests the ability of the MAVD to normalize venous flow between dialysis periods while generating the typical hemodynamics of end-to-side vein-graft anastomoses during dialysis.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3