Ultrasound-Guided Subclavian Venipuncture is More Rapidly Learned than the Anatomic Landmark Technique in Simulation Training

Author:

Tokumine Joho12,Matsushima Hisao2,Lefor Alan Kawarai3,Igarashi Hiroshi4,Ono Kazuyuki2

Affiliation:

1. Department of Anesthesia, Seikei-kai Chiba Medical Center, Chiba-shi - Japan

2. Department of Emergency and Critical Care Medicine, Dokkyo Medical University, Tochigi - Japan

3. Department of Surgery, Jichi Medical University, Tochigi - Japan

4. Department of Medical Education, Hamamatsu University School of Medicine, Shizuoka - Japan

Abstract

Purpose Both ultrasound-guided subclavian venipuncture (US-SV) and landmark-guided subclavian venipuncture (LM-SV) are important in critical care, because the clinical utility of ultrasound guidance is still debated. Education of residents and medical students should include both techniques. The aim of this study is to compare learning these two techniques in a simulation environment. Methods This study was approved by the research ethics review committee. Trainees included residents and medical students who were instructed using the “Videos in Clinical Medicine” for LM-SV, or a dedicated slide series for US-SV, using the long-axis in-plane with needle-guide technique. After the lecture, trainees attempted to perform venipuncture in a simulator. All participants performed both techniques. The procedure time from initial skin puncture to detecting back-flow of fluid from the simulated vein was measured. A procedure time over 3 min, arterial puncture, or pneumothorax was counted as a failure. The end-point for each trainee was three successive successful venipunctures without a failure. A trainee who reached the end-point was considered as having acquired adequate skill. Statistical analysis of the procedure time comparing the techniques was done using the Mann-Whitney U test. Results Twenty trainees participated in this training. Adequate skill to perform US-SV was achieved within three tries, but up to nine attempts were needed for LM-SV. One arterial puncture occurred during LM-SV. No pneumothoraxes occurred during the simulation training. Conclusions US-SV was learned more quickly than LM-SV in a simulation model.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3