Comparison of Commonly Carried Liquids Against Commercial Ultrasound Gel for Use in the Backcountry Setting

Author:

Wray Jennifer N.1,Soucy Zachary P.12,Daniel Nicholas J.12,Weinberg Nicholas E.12,Krauthamer G. Michael13,Crockett Sarah C.12,Pollack Catherine C.45,Storn Johndavid M.12

Affiliation:

1. The Geisel School of Medicine at Dartmouth College, Hanover, NH

2. Department of Emergency Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, NH

3. Department of Emergency Medicine, Gifford Medical Center, Randolph, VT

4. Department of Epidemiology, Geisel School of Medicine at Dartmouth College, Lebanon, NH

5. Department of Biomedical Data Science, Geisel School of Medicine at Dartmouth College, Lebanon, NH

Abstract

Introduction Point-of-care ultrasound (POCUS) is utilized in austere environments because it is lightweight, durable, battery powered, and portable. In austere settings, weight and space constraints are limitations to carrying dedicated ultrasound gel. Few studies have assessed commonly carried liquids as gel alternatives. The study objective was to assess the suitability of common food and personal care products as ultrasound coupling agents compared with that of commercial gel. Methods A noninferiority study compared 9 products to commercial gel. Each substance was independently tested on 2 subjects by 2 sonographers covering 8 standardized ultrasound windows. Clips were recorded, blinded, and independently graded by 2 ultrasound fellowship-trained physicians on the ability to make clinical decisions and technical details, including contrast, resolution, and artifact. A 20% noninferiority margin was set, which correlates to levels considered to be of reliably sufficient quality by American College of Emergency Physicians’ guidelines. The substances included water, soap, shampoo, olive oil, energy gel, maple syrup, hand sanitizer, sunscreen, and lotion. Results A total of 300 of 318 (94%) clips met the primary endpoint of adequacy to make a clinical decision. All media, except sunscreen, were noninferior to commercial gel in the ability to make a clinical decision (α=0.05). In terms of secondary outcomes, resolution, artifact, and contrast, all substances were noninferior to commercial gel (α=0.05). The sonographers concluded that all gel alternatives’ usability performed similarly to commercial gel, with the exception of energy gel. Conclusions Of the 9 substances tested, 8 were noninferior to commercial gels for clinical decisions. Our study indicates that several POCUS gel substitutes are serviceable to produce clinically adequate images.

Publisher

SAGE Publications

Subject

Public Health, Environmental and Occupational Health,Emergency Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3