Affiliation:
1. From the Department of Orthopaedics and Trauma, Royal Adelaide Hospital and Wakefield Orthopaedic Clinic, Adelaide, Australia
Abstract
Deficiency of the proximal pole of the scaphoid due to fracture or necrosis was treated by costo-osteochondral replacement arthroplasty using rib bone/cartilage autografts in 22 patients who were followed prospectively and assessed at a median 24 month follow-up (range, 12–72 months). Improvement of wrist function occurred in all patients with increased motion, improved grip strength and less pain. The average modified Green and O’Brien Wrist Function Score improved from 53 out of 100 preoperatively to 80 at the most recent review. All patients were graded fair or poor at initial review and all but three improved to good or excellent at the most recent assessment. Despite the absence of the scapholunate ligament, carpal alignment did not deteriorate in any patient and there were no graft non-unions or significant complications. In the short and medium term a costo-osteochondral autograft can satisfactorily restore mechanical integrity of the scaphoid proximal pole and maintain wrist motion while avoiding the potential complications of alternative replacement arthroplasty techniques.
Cited by
70 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献