The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture: A biomechanical perspective

Author:

Ramlee Muhammad Hanif,Seng Gan HongORCID,Ros Felip Antonio,Abdul Kadir Mohammed Rafiq

Funder

Ministry of Higher Education, Malaysia

Universiti Teknologi Malaysia

Universiti Kuala Lumpur - British Malaysian Institute

Universiti Kuala Lumpur

Publisher

Elsevier BV

Subject

Orthopedics and Sports Medicine,Emergency Medicine

Reference65 articles.

1. Non-reducible, open tibial plafond fractures treated with a circular external fixator (is the current classification sufficient for identifying fractures in this area?);Kapukaya;Injury,2005

2. Management of comminuted closed tibial plafond fractures using circular external fixators;Kapukaya;Acta Orthopaedic Belgia,2005

3. Hybrid external fixation in complex tibial plateau and plafond fractures: an Australian audit of outcomes;Piper;Injury,2005

4. Unilateral external fixation until healing with the dynamic axial fixator for severe open tibial fractures;Marsh;J Orthop Trauma,1991

5. Tibial plafond fractures: changing principles of treatment;Bonar;TheJournal of American Academy of Orthopaedic Surgeons,1994