Assessment of MARS-KS prediction capability for natural circulation flow in passive heat removal system
-
Published:2024-08
Issue:8
Volume:56
Page:3435-3449
-
ISSN:1738-5733
-
Container-title:Nuclear Engineering and Technology
-
language:en
-
Short-container-title:Nuclear Engineering and Technology
Author:
Lee JeheeORCID,
Park Youngjae,
Jeon Seong-Su,
Park Ju-Yeop,
Cho Hyoung Kyu
Reference36 articles.
1. Westinghouse AP1000 advanced passive plant;Schulz;Nucl. Eng. Des.,2006
2. Design of condensation heat exchanger for the PAFS (passive Auxiliary Feedwater system) of APR+ (advanced power reactor Plus);Bae;Ann. Nucl. Energy,2012
3. Optimal design of passive containment cooling system for innovative PWER;Ha;Nucl. Eng. Technol.,2017
4. K. H. Bae, S. D. Kim, Y. J. Lee, G. H. Lee, S. J. Ahn, S. W. Lim, Y. I. Kim, Enhanced safety characteristics of SMART100 adopting passive safety systems, Nucl. Eng. Des. 379, 111247.