Author:
Parrilla Claudio,Galli Jacopo,Fetoni Anna Rita,Rigante Mario,Paludetti Gaetano
Abstract
Objective To standardize the technical parameters of the erbium: yttrium-aluminum-garnet (Er:YAG) laser stapedotomy. Study Design Retrospective study of all patients with otosclerosis who underwent stapedotomy from January 2002 to January 2006. Subjects and Methods The charts of 152 consecutive patients who underwent stapedotomy were reviewed. The patients were stratified into two groups, according to the instrument used. Stapedotomies were performed in group A, with the OPMI®TwinEr: YAG laser; and in group B with manual microperforators. Results No statistically significant differences were found over all measured frequencies, between pre- and postoperative bone conduction thresholds, in each group. At the last postoperative follow-up, vertigo and nystagmus were not detected; two patients in group A and one patient in group B showed persistent tinnitus. Conclusion Er:YAG laser stapedotomy is a safe and effective procedure, with no damage of the inner ear when strict adherence to the safety parameters is observed. The Er:YAG laser is definitively suitable for stapes surgery, and represents a useful and safe tool in the armamentarium of otological microsurgery.
Subject
Otorhinolaryngology,Surgery
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献