Affiliation:
1. ‘Lago Maggiore’ Veterinary Clinic, Corso Cavour 3, 28040 Dormelletto (NO), Italy
Abstract
A percutaneous technique to place oesophageal feeding tubes in cats is described. Nineteen traumatised cats underwent different surgical procedures for facial and/or oral trauma and subsequent oesophagostomy. The tube placement was easy to perform, requiring a 14 G over-the-needle vascular catheter, a curved forceps and a 1.2 mm feeding tube. During insertion, the tube was directed aborally (normograde direction) to its definitive position in a one-step procedure. The tube was removed when the patient started to eat voluntarily. A major limit of this technique was represented by the small diameter of the feeding tube, requiring the use of a liquid diet. However, considering the absence of complications, the rapidity of the procedure and its cost efficacy, it was considered as an effective alternative to more complicated and invasive techniques, in particular if a short period of starvation is predictable.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献