Affiliation:
1. From the Department of Orthopaedics and Traumatology, Regional Hospital of Bolzano, Bolzano, Italy
Abstract
Twenty-one intraarticular palmar displaced fractures of the distal radius operated on between 1990 and 1995 were reviewed with a mean follow-up of 27.3 months (range, 8–54). Fifteen fractures were treated with palmar T-plates, two in combination with an external fixator. Five fractures were treated with external fixators and K-wires, and one fracture was treated with percutaneous K-wires and a cast. In six patients cancellous bone graft from the iliac crest was used. The most satisfactory clinical and radiological results were obtained by anatomical reconstruction of the articular surface. The favoured method remains stabilization with palmar T-plates. K-wires with a cast should only be used in simple articular fractures with a large palmar fragment.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献