Debunking the Myth: Validation of Fluorescein for Testing the Precision of Nanoliter Dispensing

Author:

Harris David L.1,Mutz Mitchell1

Affiliation:

1. Labcyte, Inc., Sunnyvale, CA

Abstract

Acoustic energy can precisely and accurately eject a droplet of liquid from a reservoir, enabling delivery of picoliter and nanoliter volumes (Ellson, R.; Mutz, M.; Browning, B.; Lee, L.; Miller, M.; Papen, R. Transfer of low nanoliter volumes between microplates using focused acoustics—automation considerations. Journal of the Association for Laboratory Automation 2003, 8(5), 29–34). Acoustic droplet ejection has been shown to be extremely precise (coefficients of variation < 2%) over a wide range of dispensed volumes (Ellson, R.; Mutz, M.; Browning, B.; Lee, L.; Miller, M.; Papen, R. Transfer of low nanoliter volumes between microplates using focused acoustics—automation considerations. Journal of the Association for Laboratory Automation 2003, 8(5), 29–34). However, measuring the performance of low-volume fluid transfers can be difficult because the data are often masked by variability in bulk dispensers and fluorescence readers used as part of the overall measurement process (Petersen, J.; Nguyen, J. Comparison of absorbance and fluorescence methods for determining liquid dispensing precision. Journal of the Association for Laboratory Automation 2005, 10(2), 82–87; Rhode, H.; Schulze, M.; Renard, S.; Zimmerman, P.; Moore, T.; Cumme, G.; Horn, A. An improved method for checking HTS/uHTS liquid handling systems. Journal of Biomolecular Screening 2004, 9, 726–733). The fluorophore used must also be stable so that thermal bleaching and photobleaching do not contribute additional variability to the measurements. This study assesses the suitability of fluorescein to measure the precision of fluid transfers of 2.5-nL DMSO droplets. The short-term and long-term stabilities of fluorescein are first qualified using a reference standard. Next, we determine the noise contribution of the filler and reader. Lastly, data are presented for the precision of 5- and 50-nL fluid transfers using this fluorescein measurement process. (JALA 2006;11:233–9)

Publisher

SAGE Publications

Subject

Medical Laboratory Technology,Computer Science Applications

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3