Abolition of Respiratory-Motion Artifact in Computed Tomography Coronary Angiography with Ultrafast Examinations: A Comparison between 64-row and 320-row Multidetector Scanners

Author:

Torres Felipe S.1,Crean Andrew M.1,Nguyen Elsie T.1,Menezes Ravi23,Doyle Deirdre1,Ayyappan Anoop P.1,Abadi Sobhi1,Paul Narinder1

Affiliation:

1. Division of Cardiothoracic Imaging, Department of Medical Imaging, Toronto General Hospital, Ontario, Canada

2. Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada

3. CT and MRI Center, Lusi Wong Early Lung Cancer Screening Program, Toronto, Ontario, Canada

Abstract

Purpose To compare the incidence of respiratory artifact in computed tomography (CT) coronary angiography performed with 64-row and 320-row multidetector scanners and to assess its effect on coronary evaluability. Methods A retrospective review of consecutive coronary angiograms performed on a 64-row multidetector CT from March to April 2007 (group 1: 115 patients, 63 men; mean age [standard deviation] 59.6 ± 12.8 years) and on a 320-row multidetector CT from March to April 2008 (group 2: 169 patients, 89 men; mean [SD] age 57.9 ± 11.6 years). Two cardiac radiologists assessed the occurrence of respiratory artifact and coronary evaluability in studies with respiratory artifacts. Unevaluable coronary segments because of motion at the same anatomical level of the respiratory artifact were considered unevaluable because of this artifact. The association between the occurrence of respiratory artifact and patient biometrics, medication, and scan parameters was examined. Results Respiratory artifacts were detected in 9 of the 115 patients from group 1 (7.8%) and in none of the 169 patients from group 2 ( P < .001). Group 1 had longer scan times (median, 9.3 seconds; range, 7.5−14.4 seconds) compared with group 2 (median, 1.5 seconds; range, 1.1−3.5 seconds; P < .001). In group 1, 4 patients (3.5%) showed unevaluable coronary segments because of respiratory artifacts, and the CT coronary angiography was repeated in 1 patient (0.9%). Conclusions Respiratory artifacts are important in CT coronary angiography performed with 64-row multidetector scanners and impair the diagnostic utility of the examination in up to 3.5% of the studies. These artifacts can be virtually eliminated with a faster scan time provided by 320-row multidetector CT.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3