Local Diagnostic Reference Levels for Typical Radiographic Procedures

Author:

Tonkopi Elena1,Daniels Cupido1,Gale Mary J.1,Schofield Stephanie C.1,Sorhaindo Vicki A.1,VanLarkin Jeanne L.1

Affiliation:

1. Diagnostic Imaging Department, QE II Health Sciences Centre, Halifax, Nova Scotia, Canada

Abstract

Purpose To establish local diagnostic reference levels (DRL) for typical radiographic examinations in a fully digital imaging institution. Methods The initial survey included 6 standard radiographic projections performed in 19 computed radiography (CR) and digital radiography (DR) rooms. Because of the expected difference in the performance, the local reference levels were analysed separately for those 2 modalities. Data of 226 average size adult patients were included in the analysis. Entrance surface dose (ESD) was calculated from the recorded radiographic techniques and tube radiation output measurements. After observing wide variations in the results of the patient survey, the examinations were repeated by using anthropomorphic phantoms. Initial efforts to understand the reasons for dose variations were focused on CR chest, abdomen, pelvis, and lumbar spine examinations. Results The average size patient doses for similar examinations were lower in the DR rooms than in the CR rooms by factors that ranged from 1.2 to 3, with the exception of the chest examination. Standardization of the CR exposure index value allowed us to decrease ESD by 21%-30%. Detector sensitivity had an insignificant effect (2%) on ESD; proper collimation lowered the dose by 17%. However, the major effect, up to 46% difference, was found because of antiscatter grids cutoff. Conclusion Modality specific local diagnostic reference levels for standard examinations have been established in a large digital imaging department with hybrid modalities. Typically the local reference values were lower than those recommended in Safety Code 35, except for CR chests. Factors that affect the dose variations have been investigated and determined.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference13 articles.

1. DIAGNOSTIC REFERENCE LEVELS FOR MEDICAL EXPOSURE OF PATIENTS: ICRP GUIDANCE AND RELATED ICRU QUANTITIES

2. International Commission on Radiological Protection Radiological Protection and Safety in Medicine. ICRP Publication 73, Annals of the ICRP 26(2) 1996 Pergamon Press Oxford

3. European Commission European guidelines on quality criteria for diagnostic radiographic images. Publication EUR 16263 EN 1996 European Commission Brussels, Belgium

4. Council of the European Union. Council Directive 97/43/Euratom (Medical Exposure Directive) of June 30, 1997, on health protection of individuals against the dangers of ionizing radiation in relation to medical exposure. OJEC 1997;L180:22–7.

5. Local diagnostic reference levels in standard X-ray examinations

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3