Negative Predictive Value of Contrast-Enhanced Ultrasound of Liver and Kidney Thermal Ablation Sites for Local Tumour Progression during Long-term Follow-up: A Retrospective Consecutive Study

Author:

Atri Mostafa1,Alrashed Abdulmohsen1,Hassan Ahmad1,Khalili Korosh1,Kim Tae Kyoung1,Jang Huynh Jung1

Affiliation:

1. Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada

Abstract

PurposeTo determine negative predictive value (NPV) of contrast-enhanced ultrasound (CEUS) to demonstrate local tumour progression (LTP) at thermal ablation (TA) sites.MethodsOur institutional review board approved this retrospective study; acquisition of consent was waived. Consecutive CEUS examinations performed between 2004-2014 for TA site evaluation on patients who could not undergo enhanced computed tomography (CT) or magnetic resonance imaging (MRI), or had inconclusive CT or MRI, were retrospectively reviewed. Those reported as no abnormal enhancement in or surrounding TA site were included. CEUS examination was considered true-negative based on stability or lack of enhancement/washout on follow-up imaging for at least 1 year, and false-negative (FN), if there was an arterially enhancing focus with wash-out at or surrounding TA site on subsequent follow-up imaging.ResultsStudy population included 56 tumours in 54 patients, 11 women, 43 men; mean age 71 years. Two patients had TA of two different hepatocellular carcinomas. Thirty-six examinations were for hepatic TA and twenty for renal TA. Lesion sizes ranged from 1 cm to 7 cm (mean 3.1 ± 1.2). Mean diameter of 7 recurrences was 13.8 mm. Overall FN rate was 12.5% (7/56). Corresponding numbers were 0% (0/20) for renal TA and 19.4% (7/36) for hepatic TA. Overall NPV of CEUS was 87.5% (49/56) (confidence interval [CI]: 78.8%–96.2%). NPV for renal TA was 100% (20/20) (CI: 100%–100%) and for hepatic TA 81.5% (29/36) (CI: 67.6 %–93.5%).ConclusionIn this cohort, CEUS showed high NPV for exclusion of LTP at renal TA sites. NPV for hepatic TA sites was high but lower than renal TA.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3