Determination of the Best Parameter for Defining the Hemodynamic Significance of an Iliac Artery Stenosis Detected on Computed Tomography Angiography

Author:

Lougheed Nick1,Jaskolka Jeff1,Beecroft Rob1,Menezes Ravi1

Affiliation:

1. Joint Department of Medical Imaging, University Health Network, Toronto General Hospital, Toronto, Ontario, Canada

Abstract

Purpose The purpose of this study was to determine the best parameter, derived from computed tomography angiography (CTA) for accurate prediction of a hemodynamically significant stenosis of the common or external iliac artery. Methods A retrospective keyword search was performed on the Radiology Information System at our tertiary academic medical centre. Reports from January 2008 to September 2013 were searched using the keywords iliac, stenosis, and pressure. Patients who had both and CTA and a pelvic angiogram with pressure measurements obtained across a potential stenosis were selected. Using 3D postprocessing software (TeraRecon, Foster City, CA), the CTAs were analysed for the following parameters of each lesion: minimum diameter of stenosis, minimum cross-sectional area of stenosis, percent narrowing of vessel diameter, and percent reduction in vessel area. The percent stenosis was calculated in reference to the outer diameter at the point of maximal narrowing and also in reference to a normal segment of vessel more distal to the stenosis. These parameters were then compared with the measured pressure gradient using receiver-operating characteristic analysis and the Mann-Whitney U test to determine which best predicted a significant stenosis, defined as a greater than 10% drop in systolic pressure across a lesion. Results One hundred and two stenoses in 83 patients (26 women, 57 men; 47-88 years old) were identified. Mean diameter of the stenosis was 2.8 mm for significant stenosis compared to 3.8 mm in nonsignificant stenoses ( P = .005). Mean minimum area for significant stenoses was 11.8 mm2 compared to 17.22 mm2 for nonsignificant stenoses ( P = .032) No other variables showed a significant difference between significant and nonsignificant stenoses. A minimum diameter of ≤4.0 mm at the level of a stenosis is 92% sensitive and 48% specific for predicting a hemodynamically significant iliac artery stenosis, with a positive predictive value of 88%. Conclusions A simple measurement of the minimum diameter of an iliac artery at the level of stenosis is the best predictor of the hemodynamic significance of a stenosis in the common or external iliac artery.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3