Image Quality in Low-dose Multidetector Computed Tomography: A Pilot Study to Assess Feasibility and Dose Optimization in Whole-body Bone Imaging

Author:

Gleeson Tadhg G.1,Byrne Brenda2,Kenny Pat2,Last Jason3,Fitzpatrick Patricia4,O'Gorman Peter5,Eustace Steven J.1

Affiliation:

1. Department of Radiology and Diagnostic Imaging, Mater Misericordiae University Hospital, Dublin, Ireland

2. Department of Medical Physics, Mater Misericordiae University Hospital, Dublin, Ireland

3. Department of Anatomy, University College Dublin, Earlsfort Terrace, Dublin, Ireland

4. School of Public Health and Population Science, University College Dublin, Earlsfort Terrace, Dublin, Ireland

5. Department of Haematology, Mater Misericordiae University Hospital, Dublin, Ireland

Abstract

Objective To study the impact of dose parameters on image quality at whole-body low-dose multidetector computed tomography (CT) in an attempt to derive parameters that allow diagnostic quality images of the skeletal system without incurring significant radiation dose in patients referred for investigation of plasma cell dyscrasias. Methods By using a single cadaver, 14 different whole-body low-dose CT protocols were individually assessed by 2 radiologists, blinded to acquisition parameters (kVp and mAs, reconstruction algorithm, dose reduction software). Combinations of kVps that range from 80-140 kVp, and tube current time product from 14–125 mAs were individually scored by using a Likert scale from 1–5 in 4 separate anatomical areas (skull base, thoracic spine, pelvis, and distal femora). Correlation between readers scores and effective doses were obtained by using correlation coefficient statistical analysis, statistical significance was considered P < .01. Interobserver agreement was assessed by using a Bland and Altman plot. Interobserver agreement in each of the 4 anatomical areas was assessed by using kappa statistics. A single set of parameters was then selected for use in future clinical trials in a cohort of patients referred for investigation of monoclonal gammopathy, including multiple myeloma. Results Several sets of exposure parameters allowed low-dose whole-body CT to be performed with effective doses similar to skeletal survey while preserving diagnostic image quality. Individual reader's and average combined scores showed a strong inverse correlation with effective dose (reader 1, r = −0.78, P = .0001; reader 2, r = −0.75, P = .0003); average combined scores r = −0.81, P < .0001). Bland and Altman plot of overall scores shows reasonable interobserver agreement, with a mean difference of 1.055. Conclusion Whole-body low-dose CT can be used to obtain adequate CT image quality to assess normal osseous detail while delivering effective doses similar to those associated with conventional radiographic skeletal survey.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3