Characterization of extended-spectrum β-lactamase (ESBL)-producing Kuwait and UK strains identified by the Vitek system, and subsequent comparison of the Vitek system with other commercial ESBL-testing systems using these strains

Author:

Dashti A. A.1,West P.1,Paton R.2,Amyes S. G. B.2

Affiliation:

1. Medical Laboratory Sciences, Health Science Centre, Kuwait University, Kuwait

2. Molecular Chemotherapy, Centre for Infectious Diseases, University of Edinburgh, Edinburgh EH16 4SB, UK

Abstract

Two hundred and fifty-one unique patient isolates of Klebsiella pneumoniae (123), Escherichia coli (114), Klebsiella oxytoca (7), Enterobacter cloacae (5) and Citrobacter freundii (2), flagged as extended-spectrum β-lactamase (ESBL) positive by the Vitek system (GNS-526 card), were collected. These strains were isolated from a variety of clinical specimens submitted to the clinical bacteriology laboratories of the Royal Infirmary of Edinburgh (RIE), Edinburgh, UK (and associated GP practices), Hairmyers Hospital, Glasgow, UK, and the Amiri and Farwania Hospitals, Kuwait. Of the 101 RIE strains tested, 15 E. coli strains were found to be ESBL negative by Etest ESBL strips. On retesting the 15 E. coli strains with the Vitek GNS-532 card, 14 were found to be ESBL negative, despite being originally flagged as ESBL positive. The remaining 236 ESBL-producing strains were also subjected to the double disc-diffusion (DDD) technique for the detection of ESBLs. Of these, two were false negatives by Etest ESBL test strips (using both cefotaxime and ceftazidime strips), and 38 were false negatives by the DDD method. The Etest false-negative ESBL-producing strains of K. pneumoniae were positive by DDD. Technically, the Vitek method was the least demanding method to perform, as it was an integral part of the routine susceptibility test card. Etest strips were reliable, but were the most expensive of all the techniques used. The DDD test, while relatively inexpensive, was technically subjective, and in our hands, seven of the ESBL-positive strains that were confirmed by the other two techniques were not detected. Despite the false-positive ESBL-producing E. coli strains, the Vitek susceptibility card with its integral ESBL test offers the clinical laboratory a valuable and quick option to screen for ESBL-producing Klebsiella spp. and E. coli as part of the routine laboratory methodology.

Publisher

Microbiology Society

Subject

Microbiology (medical),General Medicine,Microbiology

Reference14 articles.

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3