A novel high-throughput method for molecular serotyping and serotype-specific quantification of Streptococcus pneumoniae using a nanofluidic real-time PCR system

Author:

Dhoubhadel Bhim Gopal1,Yasunami Michio1,Yoshida Lay-Myint1,Thi Hien Anh Nguyen2,Thi Thu Huong Vu2,Thi Thuy Ai Nguyen3,Watanabe Kiwao1,Suzuki Motoi1,Morimoto Konosuke1,Dang Duc Anh2,Ariyoshi Koya1

Affiliation:

1. Department of Clinical Medicine, Institute of Tropical Medicine, Nagasaki University, Japan

2. Department of Bacteriology, National Institute of Hygiene and Epidemiology, Hanoi, Vietnam

3. Department of Microbiology, Khanh Hoa General Hospital, NhaTrang, Vietnam

Abstract

Serotype-specific quantification data are essential for elucidating the complex epidemiology of Streptococcus pneumoniae and evaluating pneumococcal vaccine efficacy. Various PCR-based assays have been developed to circumvent the drawback of labour-intensive and time-consuming culture-based procedures for serotype determination and quantification of pneumococcus. Here, we applied a nanofluidic real-time PCR system to establish a novel assay. Twenty-nine primer pairs, 13 of which were newly designed, were selected for the assay to cover 50 serotypes including all currently available conjugate and polysaccharide vaccine serotypes. All primer pairs were evaluated for their sensitivity, specificity, efficiency, repeatability, accuracy and reproducibility on the Fluidigm Biomark HD System, a nanofluidic real-time PCR system, by drawing standard curves with a serial dilution of purified DNA. We applied the assay to 52 nasopharyngeal swab samples from patients with pneumonia confirmed by chest X-ray to validate its accuracy. Minimum detection levels of this novel assay using the nanofluidic real-time PCR system were comparable to the conventional PCR-based assays (between 30 and 300 copies per reaction). They were specific to their targets with good repeatability (sd of copy number of 0.1), accuracy (within ±0.1 fold difference in log10 copy number) and reproducibility (sd of copy number of 0.1). When artificially mixed DNA samples consisting of multiple serotypes in various ratios were tested, all the serotypes were detected proportionally, including a minor serotype of one in 1000 copies. In the nasopharyngeal samples, the PCR system detected all the culture-positive samples and 22 out of 23 serotypes identified by the conventional method were matched with PCR results. We conclude that this novel assay, which is able to differentially quantify 29 pneumococcus groups for 45 test samples in a single run, is applicable to the large-scale epidemiological study of pneumococcus. We believe that this assay will facilitate our understanding of the roles of serotype-specific bacterial loads and implications of multiple serotype detections in pneumococcal diseases.

Publisher

Microbiology Society

Subject

Microbiology (medical),General Medicine,Microbiology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3