Use of Sysmex UF-5000 flow cytometry in rapid diagnosis of urinary tract infection and the importance of validating carryover rates against bacterial count cut-off

Author:

Haugum Kjersti12,Haugan Maria Schei2,Skage Jannicke2,Tetik Mariann2ORCID,Jakovljev Aleksandra2,Nilsen Hans-Johnny Schjelderup2ORCID,Afset Jan Egil12ORCID

Affiliation:

1. Department of Clinical and Molecular Medicine, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway

2. Department of Medical Microbiology, St. Olavs Hospital, Trondheim, Norway

Abstract

Introduction. Urinary tract infections are common bacterial infections worldwide. Urine culture is the gold standard method to identify and quantify the presence or absence of bacteria in urine. Flow cytometry, which can differentiate and quantify multiple particles (including bacteria) in the urine, presents an alternative method for rapid screening to rule out bacteriuria. Hypothesis. Adding flow cytometry to identify urine samples without bacteriuria could substantially reduce the number of urine samples that need to be cultured as well as the response time for negative results. However, the level of instrument rinsing between samples could affect sample-to-sample carryover rate, a concept given little attention in previous studies. Aim. We aimed to evaluate urine flow cytometry as a rapid screening method to identify urine samples without significant bacterial growth, including analyses of cross-contamination and sample-to-sample carryover rate. Methodology. We analysed 3919 urine samples by quantitative urine culture and flow cytometry screening (Sysmex UF-5000). Receiver operator characteristic (ROC) curve analyses were used to test method agreement to identify: (a) positive vs. negative culture and (b) mixed vs. pure culture. In addition, we performed carryover and cross-contamination studies. Results. ROC curve analyses identified bacterial count (BACT ml−1) and leucocyte count (WBC µl−1) as possible predictors of bacterial growth in the total material and subpopulations, except pregnant women (n=451). This subgroup was excluded from further analyses, leaving a final 3468 urine samples. Area under the ROC curve was 0.94 (95 % CI 0.93–0.95) and 0.81 (95 % CI 0.79–0.82) for bacterial and leucocyte count, respectively. A bacterial count cut-off of 30 BACT ml−1 resulted in 95.2 % sensitivity and 91.2 % negative predictive value, resulting in approximately 30 % of urine samples that could be reported as negative without culture. Use of high-level rinse modes was necessary to ensure carryover rates <0.05 %. Conclusion. Flow cytometry is a suitable and rapid method to rule out urine samples without significant bacterial growth. Rinses between samples should be adjusted, depending on the cut-off used, to prevent sample-to-sample carryover, whereas cross-contamination can be eliminated by the use of separate urine aliquots for flow cytometry analysis and urine culturing respectively.

Funder

st. olavs hospital universitetssykehuset i trondheim

Publisher

Microbiology Society

Subject

Microbiology (medical),General Medicine,Microbiology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3