Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients

Author:

Lunz AndreORCID,Von Falkenhayn Moritz,Jaeger Sebastian,Reiner Tobias,Merle Christian,Streit Marcus R,Renkawitz Tobias,Innmann Moritz M

Abstract

Purpose: We aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients.Patients and methods: This is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive total hip replacements (THRs) using a cementless, press-fit cup (Allofit, Zimmer, Warsaw, IN, USA) performed between 1999 and 2001. 28-mm metal-on-metal (MoM) and ceramic-on-conventionally not highly crosslinked polyethylene (CoP) bearings were used in 71% and 28%, respectively. Median patient age at surgery was 52 (range 21–60) years. Kaplan–Meier survival analysis was conducted for different endpoints.Results: The 22-year survival rate for the endpoint aseptic cup or inlay revision was 94% (95% confidence interval [CI] 87–96) and 99% (CI 94–100) for aseptic cup loosening. 20 patients (21 THRs; 17%) had died and 5 (5 THRs; 4%) were lost to follow-up. No THR showed evidence of radiographic cup loosening. Osteolysis was observed in 40% of THRs with MoM and 77% with CoP bearings. 88% of THRs with CoP bearings showed significant polyethylene wear.Conclusion: The investigated cementless press-fit cup, which is still in clinical use today, showed excellent long-term survival rates in patients under the age of 60 years at surgery. However, osteolysis due to polyethylene and metal wear was frequently observed and is a matter of concern in the third decade after surgery.

Publisher

Medical Journals Sweden AB

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Reference28 articles.

1. Ben-Shlomo Y, Blom A, Boulton C, Brittain R, Clark E, Dawson-Bowling S, et al. National Joint Registry Annual Reports. Available from https://www.ncbi.nlm.nih.gov/books/NBK587525/.

2. Kärrholm J, Rogmark C, Naucler E, Nåtman J, Vinblad J, Mohaddes M, et al. Swedish Hip Arthroplasty Register Annual report 2019; 2021. doi: 10.18158/H1BdmrOWu.

3. Grimberg A, Jansson V, Lützner J, Melsheimer O, Morlock M, Steinbrück A. EPRD Jahresbericht 2021; 2021.

4. Kurtz S M, Gawel H A, Patel J D. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 2011; 469: 2262-77. doi: 10.1007/s11999-011-1872-4.

5. Moon N H, Shin W C, Do M U, Kang S W, Lee S M, Suh K T. Wear and osteolysis outcomes for highly cross-linked polyethylene in primary total hip arthroplasty compared with conventional polyethylene: a 15- to 18-year single-centre follow-up study. Hip Int 2021; 31: 526-32. doi: 10.1177/1120700019896970.