Abstract
Background and purpose: The use of patient-specific positioning guides (PSPGs) in total knee arthroplasty (TKA) has been advocated as a means of improving patient outcomes, but the reception of PSPGs has been mixed. The aim of our study was to compare patient-reported outcomes (KOOS, NRS-11, EQ-5D-3L, EQ-VAS) after TKA using PSPG with conventional instrumentation (CI) to determine whether there is a discernible clinical benefit to using PSPGs.Patients and methods: This multicenter randomized controlled trial (RCT) followed 77 patients who were randomly assigned to 1 of 2 cohorts between September 2011 and January 2014—one receiving TKA with PSPGs (from Materialise NV) and one receiving TKA with CI—with each cohort followed up until 5 years after the operation. The Vanguard Cruciate Retaining Total Knee System and Refobacin Bone Cement R were used in all operations. KOOS was evaluated using confidence intervals, with differences of less than 10 KOOS units between the cohorts interpreted as indicating the absence of a clinically meaningful difference.Results: No significant differences were found in any of the measured clinical outcomes—KOOS, NRS-11, EQ-5D-3L, EQ-VAS, range of motion, or radiolucent lines scoring—between the cohort operated on using PSPG and the cohort operated on using CI after 5 years of follow-up.Conclusion: There was no statistically significant effect of PSPGs on patient-reported outcomes or range of motion in TKA.
Publisher
Medical Journals Sweden AB
Subject
Orthopedics and Sports Medicine,General Medicine,Surgery
Reference24 articles.
1. Longstaff L M, Sloan K, Stamp N, Scaddan M, Beaver R. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 2009; 24: 570-8. doi: 10.1016/j.arth.2008.03.002.
2. Thiele K, Perka C, Matziolis G, Mayr H O, Sostheim M, Hube R. Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J Bone Joint Surg Am 2015; 97(9): 715-20. doi: 10.2106/JBJS.M.01534.
3. Mont M A, Urquhart M A, Hungerford D S, Krackow K A. Intramedullary goniometer can improve alignment in knee arthroplasty surgery. J Arthroplasty 1997; 12(3): 332-6. doi: 10.1016/S0883-5403(97)90031-0
4. Krackow K A, Bayers-Thering M, Phillips M J, Bayers-Thering M, Mihalko W M. A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. Orthopedics 1999; 22(7): 698-702.
5. Budhiparama N C, Lumban-Gaol I, Ifran N N, Parratte S, Nelissen R. Does accelerometer-based navigation have any clinical benefit compared with conventional TKA? A systematic review. Clin Orthop Relat Res 2019; 477(9): 2017-29. doi: 10.1097/CORR.0000000000000660.