Abstract
The use of commercial data loggers and gypsum blocks to monitor the matric
potential of water in soil was evaluated in the laboratory and at 2 field
sites. A set of calibration resistors that simulated a matric potential range
of —20 to —2120 kPa was developed that showed close
agreement with data that was originally used to develop algorithms for the
loggers. Data loggers used in experiments were calibrated against the
resistors so output values could be re-scaled to that of the resistor set.
Close agreement was found between the matric potential of soil, which was
estimated from filter papers, and re-scaled logged matric potential values for
gypsum blocks embedded in containers of soil maintained at a range of water
contents in the laboratory. Re-scaled logged soil matric potential recorded at
2 field sites also compared favorably with filter paper estimates for soil
sampled adjacent to where gypsum blocks were buried. It was concluded that,
provided individual data loggers were standardised to the same matric
potential scale using either calibrated resistors or soil of known matric
potential, the gypsum block technique provided an economical and accurate
measure of soil water status.