Author:
Budd GM,Brotherhood JR,Hendrie AL,Jeffery SE,Beasley FA,Costin BP,Zhien W,Baker MM,Hoschke BN,Holcombe BV,Cheney NP,Dawson MP
Abstract
Light, heavy, and encapsulating clothing were compared in a climatic chamber during 60 minutes of moderate exercise (energy expenditure 382-464 W) in warm, dry conditions with no added radiant heat (air and mean radiant temperature 30°C, relative humidity 33 %, air velocity 0.5 m s-1). The results showed that high insulation and reduced ventilation restricted the evaporation of sweat and thus hindered the dissipation of metabolic heat. These adverse effects were apparent in (1) a reduced cooling efficiency of sweat and hence a higher sweat rate; (2) increased heat storage, cardiovascular strain, discomfort, and fatigue; and (3) a failure to attain thermal equilibrium even after 60 minutes of work. Comparison with the effects of fire, previously reported, on lightly dressed firefighters showed that the above penalties would outweigh any benefit that extra insulation or encapsulation could confer during wildland fire suppression with hand tools.
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献