High Throughput Determination of BTEX by a One-Step Fluorescence Polarization Immunoassay

Author:

Eremin Sergei A.,Knopp Dietmar,Niessner Reinhard,Hong Ji Youn,Park Song-Ja,Choi Myung Ja

Abstract

Environmental Context.Benzene, toluene, ethylbenzene, and xylenes (BTEX) are used as solvents in paints and coatings and are constituents of petroleum products. BTEX can contaminate air, water or soil and is toxic; benzene, in particular, is a recognized human carcinogen. Most existing methods for detecting BTEX are time-consuming, complicated and very expensive for routine screening. A rapid immunoassay of BTEX is presented that greatly simplifies environmental monitoring of water contamination. Abstract.For the rapid screening of BTEX (benzene, toluene, ethylbenzene, xylenes), a fluorescence polarization immunoassay (FPIA) was developed using the fluorescence polarization analyzer Abbott TDx. Several fluorescence-labelled tracers were synthesized by binding ethylenediamine fluorescein thiocarbamyl (EDF) to various substituted phenylcarboxylic acids. The binding of 27 tracers with two antisera that can be considered as class-specific for BTEX was investigated to select optimal tracer–antibody pairs. Significant differences were found in binding, titer, sensitivity, and assay kinetics. A best pair of anti-BTEX antiserum and EDF-labelled p-tolylacetic acid tracer was selected for FPIA. To simplify the method, an immunocomplex single reagent was prepared to detect BTEX by a one-step FPIA. One-step FPIA is a rapid homogeneous type of immunoassay that has only one pipetting step, does not need separation of free and bound analyte and can be performed at room temperature. The within-run coefficient of variation was ranged between 3.4% and 5.7%. Furthermore, if the measurement can be done at constant temperature, standards for every assay run are unnecessary. Cross-reactivity studies of petroleum compounds and a BTEX mixture indicated that p-xylene was most reactive with a limit of detection (LOD) of 0.22 µg mL−1 in 50 µL of sample. The LOD for toluene and benzene was 2.1 and 11 µg mL−1 respectively. The immunocomplex single reagent has proven to be significantly more stable than the corresponding solutions of antibody and tracer.

Publisher

CSIRO Publishing

Subject

Geochemistry and Petrology,Environmental Chemistry,Chemistry (miscellaneous)

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3