233 NON-CROSS-CONTAMINATION OF BOVINE EMBRYOS WITH MICROBES USING THE OPS VITRIFICATION SYSTEM

Author:

Bielanski A.,Hanniman A.

Abstract

Here we report on the outcome of the application of vitrification open pulled straw (OPS) technology on the sanitary status of embryos exposed to pathogenic agents and cryopreserved using the commercial kit Vit-SeT� (Minitube Canada, Ingersoll, Ontario, Canada). The Vit-SeT consists of 3 stainless steel chambers: the first for cooling the 0.5-mL AI straws, the second for vitrification of OPS straws, and the third for loading OPS into the AI straws. The CBC 0.5-mL straws (Cryo Bio System, Paris, France), OPS straws (Minitube Canada), and the heat sealer were used. The investigation involved: (1) pressure seal testing the CBC straws; (2) testing LN for contamination after vitrification; (3) testing the surface of the CBC straws; and (4) testing the contents of OPS straws and vitrified embryos for cross-contamination. In the first Exp., CBC straws were heat sealed at one end and the other end was connected to a compressor with a manometer. The straws were then tested for air leaks in water. In Exp. 2, OPS straws were loaded by capillary aspiration of clean or contaminated cultures (3 � 108 E. coli, 13 � 108 P. aeruginosa, or 105 BVDV TCID50 mL-1, NY strain), then vitrified in LN (chamber 2) in random order, inserted into the CBC straws (chamber 3), and heat sealed at a reading of 225 on the sealer dial. In Exp. 3, IVF embryos were either exposed or not to the microbe cultures for 1 h, loaded into OPS (5 embryos per straw), and then vitrified and processed as described in Exp. 2. After vitrification, OPS straws were retrieved from CBC straws and thawed according to the original methodology (Vajta et al. 1997 Cryo-Lett. 18, 191–195). For bacterial isolation, standard methodology was used, and BVDV was detected by virus isolation followed by immunoperoxydase staining. In Exp. 1, no air leaks were detected up to 20 mm Hg pressure at the heat-sealed end of CBC straws (n = 15). In Exp. 2, two samples of LN tested positive for E. coli (after immersion of 10 OPS, chamber 2). All remaining samples of LN after vitrification of OPS tested negative for pathogenic agents. Surfaces of the 0.5-mL straws all tested negative (chamber 3). The pathogenic agents were retrieved from all of the positive control OPS straws (n = 15). In Exp. 3, all tested samples of LN and surfaces of 0.5-mL straws were negative. The pathogenic agents retrieved from samples of control embryos previously exposed to pathogens were as follows: E. coli, 5/15; P. aeroginosa, 8/15; and BVDV, 2/15. All samples containing embryos not exposed to pathogens, surfaces of 0.5-mL straws, and LN all tested negative. On the basis of limited experimental work, it is concluded that the potential for cross-contamination of samples by application of the Vit-SeT for vitrification of embryos using OPS is negligible if: (1) LN in the chambers is frequently replaced and the chambers are disinfected between embryo donors, and (2) the protective straws (0.5-mL, AI) are applied over OPS and are properly sealed. These straws should be used without a cotton plug. However, the obtained results should be not extrapolated to other means of so-called 'sterile' methods of vitrification without specific testing.

Publisher

CSIRO Publishing

Subject

Developmental Biology,Endocrinology,Genetics,Molecular Biology,Animal Science and Zoology,Reproductive Medicine,Biotechnology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3