Abstract

Highlights. Non-invasive method for the assessment of the mobility and deformation of the wire element of the bioprosthesis in the cardiac cycle based on the developed mathematical algorithm is presented. Numerical analysis of the behavior of the wire element of the “TiAra” bioprosthesis is shown for the first time. The developed method can be used for other medical devices as well.Aim. To develop a method for non-invasive assessment of the mobility and deformation of the wire element of the aortic heart valve bioprosthesis in the cardiac cycle based on mathematical processing of visual medical data.Methods. Multidetector computed tomography data of patient P. (male, 66 years old), who received the “TiAra” aortic bioprosthesis (NeoCor CJSC, Kemerovo), were used for the study. Using the built-in tools in the Mimics Medical Image Processing Software (Materialize, Belgium), based on the radio density, 5 stages of movement of  the  wire  element  of  the  bioprosthesis  were  reconstructed  in  the  form  of 3D-models.  The  differences between  the  models,  characterizing  deformation in the cardiac cycle, were quantitatively assessed using a proprietary Matlab algorithm (The MathWorks, USA), calculating the distance between similar points. Moreover, obtained data on displacements was used in the numerical study of the stress-strain state of a 3D-model of the wire element by the finite element method in the Abaqus/CAE software (Dassault Systèmes SE, France).Results. The proposed method for assessing the mobility of the wire element made it possible to quantitatively evaluate the biomechanics of the “TiAra” stentless bioprosthesis based on multidetector computed tomography, a non-invasive clinical tool. The movements that the bioprosthesis undergoes during the cardiac cycle (the maximum value is 2.04 mm in the radial direction) are comparable to the movement of the aortic root of a healthy patient. The results of the numerical modeling of the stress state of the wire element did not indicate high amplitudes (peak value – 564 MPa) that would be capable of causing critical damage to the wire. It allows us to confirm the clinical safety of the bioprosthesis in real conditions like asymmetric and uneven loads. Moreover, deformations observed in the bioprosthesis are similar in the amplitude to the displacements of the aortic root described in the literature, which highlights the main feature of the bioprosthesis – ensuring the physiological biomechanics throughout the cardiac cycle.Conclusion. The presented method of qualitative computer assessment of the movement of the wire element of heart valve prosthesis using the “TiAra” bioprosthesis as an example demonstrates its validity as a tool for studying prosthesis functioning.

Publisher

NII KPSSZ

Subject

Cardiology and Cardiovascular Medicine,Critical Care and Intensive Care Medicine,Rehabilitation,Emergency Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3