Fluoroscopic measurements of the glenohumeral joint position and space in true anteroposterior and axillary views – a reliability study

Author:

Makhija M.1,Sethi J.1,Kataria C.2,Singh H.3,Phadke V.4

Affiliation:

1. Amity Institute of Physiotherapy, Amity University Campus, Sector-125, Noida 201301, Uttar Pradesh, India.

2. Indian Spinal Injuries Centre-Institute of Rehabilitation Sciences, Sector-C, Vasant Kunj, New Delhi 110070, India.

3. Orthopedics Department, Indian Spinal Injuries Centre, Sector-C, Vasant Kunj, New Delhi 110070, India.

4. Research Department, Indian Spinal Injuries Centre, Sector-C, Vasant Kunj, New Delhi 110070, India.

Abstract

Two-dimensional (2D) fluoroscopy has been used in shoulder pathologies to estimate the humeral head position (HHP) in the true anteroposterior (AP) view. However, there is a lack of evidence regarding the reliability estimating it in the axillary view and in measuring the shoulder joint space width (JSW). True AP view images (n=36) of subjects with adhesive capsulitis were taken in supine in multiple arm abduction positions. The axillary view images (n=48) were taken in supine and prone in 75° of abduction. The HHP was assessed in the glenoid reference frame. The position and radius of the humeral head along with the superior, inferior, anterior, posterior, and middle JSWs were measured in each image. All the images were coded and randomly presented twice to a physiotherapist at a gap of 48-72 h for intra-rater reliability and to 2 therapists and an orthopaedic surgeon for inter-rater reliability. Reliability was expressed using intraclass correlation coefficients (ICC) and standard error of measurement (SEM). In both the views, inter-rater, and intra-rater reliability was excellent for the radius of the humeral head (inter-rater – 0.95-0.97 and intra-rater -0.98)], moderate (ICC: 0.70 and 0.76), and excellent (ICC: 0.89 and 0.93) for HHP. The reliability for JSWs was moderate to good (ICC: 0.66-0.82) for inter-rater and good to excellent (ICC: 0.75-0.95) for intra-rater analysis. The SEM for HHP and JSWs were <0.4 mm for intra-rater analysis, and <0.7 mm for inter-rater reliability in both views. The study demonstrated that the glenohumeral arthrokinematic parameters can be measured with good to excellent levels of reliability when using 2 D fluoroscopy. The study is part of a clinical trial (Clinical Trial Registry India: CTRI/2018/12/016657).

Publisher

Wageningen Academic Publishers

Subject

Physiology (medical),Veterinary (miscellaneous),Orthopedics and Sports Medicine,Physiology,Biochemistry,Endocrinology, Diabetes and Metabolism,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3