Comparison of novel wearable cardiac monitors to yield accurate exercising ECG and heart rate data in horses

Author:

Haughan J.1,Manriquez M.2,Cohen N.D.2,Robinson M.A.13,de Solis C. Navas1

Affiliation:

1. Department of Clinical Studies, University of Pennsylvania School of Veterinary Medicine, New Bolton Center, 382 West Street Road, Kennett Square, PA 19348, USA.

2. Department of Large Animal Clinical Sciences, College of Veterinary Medicine & Biomedical Sciences, Texas A&M University, College Station, TX 77843-447, USA.

3. Pennsylvania Equine Toxicology & Research Center, West Chester University, 220 E. Rosedale Ave West Chester, PA 19382, USA.

Abstract

Exercise associated deaths (EADs) in horses are a problem for the equestrian industry. Sudden death (SD) is responsible for approximately 20% of EADs. The underlying cause of SD is suspected to be cardiovascular disease but often cannot be determined post-mortem. User-friendly cardiac monitors are needed for large scale investigations of arrhythmias associated with SD in horses. We hypothesised that novel wearable devices would provide exercising electrocardiograms (ECGs) of sufficient diagnostic quality for this purpose. Diagnostic quality of ECGs generated by two wearable devices (W2nd and Polar Equine) were compared to simultaneous recordings with a telemetry unit (Televet) in 5 Thoroughbreds completing 43 separate submaximal exercise tests on a high-speed treadmill. Maximal heart rate (HRmax) generated by mobile applications (HRmaxapp), HRmax after manual correction (HRmaxcorr), percentage of diagnostic ECGs (%diag) at the gallop, and overall quality assessed by visual analogue scale (VAS) were assessed by a blinded observer. HRmaxcorr did not differ significantly between groups. HRmaxapp was significantly lower for W2nd (166.8/min, 95% confidence interval (CI): 160.5-173.1/min) but did not differ significantly between Televet (178.8/min 95% CI: 165.8-191.1/min) and Polar (181.3/min, 95% CI: 174.5-188.1/min). HRmaxcorr was accurate and precise in all runs. HRmaxapp was within a priori limits of agreement in 16/23 W2nd and 18/19 Polar recordings. %diag was significantly lower (77.1%, 95% CI: 67.4-86.8) for W2nd than Polar (100%, 95% CI: 89.9-110.3). VAS was lower for W2nd (46.2, 95% CI: 35.5-57.0) than Polar (90.6, 25% CI: 79.4-101.9). In conclusion, wearable devices appear to be promising tools for investigation of equine exercising arrhythmias in large-scale studies.

Publisher

Wageningen Academic Publishers

Subject

Physiology (medical),Veterinary (miscellaneous),Orthopedics and Sports Medicine,Physiology,Biochemistry,Endocrinology, Diabetes and Metabolism,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3