Performance Comparisons of Conventional and Line-Focused Surface Raman Spectrometers

Author:

Ramsey Jeremy1,Ranganathan Srikanth1,McCreery Richard L.1,Zhao Jun1

Affiliation:

1. Department of Chemistry, The Ohio State University, 100 W. 18th Ave. Columbus, Ohio (J.R., S.R., R.L.M.); and Chromex, Inc., 2705 B Pan American, Albuquerque, New Mexico 87107 (J.Z.)

Abstract

Four Raman spectrometer configurations were compared for obtaining spectra of surface monolayers, including a new design that employed a line rather than point focus. Each spectrometer used a 514.5 nm laser and charge-coupled device (CCD) detector, but they differed in collection efficiency and sampling optics. Previously defined figures of merit for Raman signal and signal-to-noise ratio (SNR) were determined for each spectrometer, to aid quantitative comparison. The figure of merit for SNR, FSNR, is demonstrated to be useful for comparisons because it permits prediction of SNR for a given spectrometer, sample, and measurement conditions. A rigorous definition of FSNR is based on power density and takes into account the laser damage threshold of the sample. A simpler but less rigorous definition is based on laser power at the sample rather than power density and may be more useful to users who rarely determine the laser spot size. A new spectrometer design employing line focusing and collection is presented, with f/2 optics and a 6 mm slit image at the CCD. A proprietary aberration correction prevents slit image curvature common to most spectrographs with low f/#, and permits full height binning of the CCD. The line-focused spectrometer yielded an SNR and FSNR which are comparable to those for a point focus using the same collection optics and slightly lower than those for the most efficient spectrograph examined. However, the line focus permitted much lower power densities to be employed, or yielded much larger signal for the same power density at a point focus. In quantitative terms, the new line-focused design yielded an SNR which is 67 times that of the best point-focused system, for the same sample, measurement time, and laser power density.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3