Variations in Predicted Values from Near-Infrared Spectra of Samples in Vials by Using a Calibration Model Developed from Spectra of Samples in Vials: Causes of the Variations and Compensation Methods

Author:

Watari Masahiro1,Du Yiping1,Ozaki Yukihiro1

Affiliation:

1. Environmental and Analytical Products Business Division, Yokogawa Electric Corporation, Musashino 180-8750, Japan (M.W.); Department of Chemistry and Research Center for Near-Infrared Spectroscopy, School of Science and Technology, Kwansei-Gakuin University, Sanda 669-1337, Japan (M.W., Y.O.); and Research Center of Analysis and Testing, East China University of Science and Technology (Y.D.)

Abstract

The causes and compensation methods of variations in the predicted values from near-infrared (NIR) spectra of samples in vials by using a calibration model developed from spectra of samples in vials were studied. From the viewpoint of the path length and the peak height of spectra in the NIR region, vials with 1 mL volume (external diameter: 8 mm, inside diameter: about 6 mm, length: 40 mm) were selected as disposable vials for the samples. To investigate the causes of the variations in the predicted values, the optical path lengths and transmittance spectra of empty vials in five lots produced during the last four years were examined. The results showed that there were some differences in the path lengths of the vials and in the intensities of peaks near 7130 and 4515 cm−1, which were attributed to the hydroxyl groups in the spectra of the vials among the five lots. The calibration models for the concentration of isopropyl alcohol (IPA) in toluene contained in vials of the same lot were developed. To search the pretreatment methods for the best calibration model with small variations in the predictive values of the samples in the vials, six kinds of pretreatments (no pretreatment, baseline correction, first derivative, second derivative, multiplicative scattering correction (MSC), and standard normal variate (SNV)) were compared. The results indicated that MSC is a very effective method with small variation in the predicted values from the spectra of samples in vials. It was found that the variations in the predicted values are caused mainly by variations in the path lengths of vials. In real quality control, the NIR-chemometrics method is requested for long-term traceability and good reproducibility of the predictive value. Therefore, it is crucial to watch changes in the path length under a fixed path length as a reference. From this standpoint, modified MSC, which uses a particular spectrum as a reference instead of the average spectrum of a sample set, was proposed in the present study, and it was demonstrated that the variations due to the individual differences in the vials can not only be compensated, but the path lengths of vials could also be estimated by the modified MSC. Moreover, a calibration model for the toluene concentration in silicone oil was developed to confirm the effects of modified MSC by using another sample set. The results showed that the compensation of vial path lengths using the modified MSC is also useful for other samples, similar to the case of the sample of IPA in toluene.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Reference15 articles.

1. A Review of Process near Infrared Spectroscopy: 1980–1994

2. Siesler H. W., in Near-Infrared Spectroscopy-Principles, Instruments, Applications, Siesler H. W., Ozaki Y., Kawata S. and Heise H. M, Eds. (Wiley-VCH, Weinheim, 2002), p. 247.

3. Ozaki Y. and Amari T, in Spectroscopy in Process Analysis, Chalmers J. M. Ed. (Sheffield Academic Press, New York, 2000), p. 53.

4. Tate J. D., Chauvel P., Guenard R. D. and Harner R, Handbook of Vibrational Spectroscopy, Chalmers J. M. and Griffiths P. R, Eds. (John Wiley and Sons, Chichester, 2002), Vol. 4, p. 2737.

5. Kemeny G. J., in Handbook of Near-Infrared Analysis, Burns D. A. and Ciurczak E. W, Eds. (Marcel Dekker, New York, 2001), p. 729.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3