Determination of Adsorbed Protein Concentration in Aluminum Hydroxide Suspensions by Near-Infrared Transmittance Spectroscopy

Author:

Lai Xuxin1,Zheng Yiwu1,Jacobsen Susanne1,Larsen Jørgen N.1,Ipsen Henrik1,Løwenstein Henning1,Søndergaard IB1

Affiliation:

1. Enzyme and Protein Chemistry, Department of Systems Biology, Building 224, Søltofts Plads, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark (S.J.); ALK-Abelló A/S, Bøge Allé 6-8, DK-2970 Hørsholm, Denmark (X.L., Y.Z., J.N.L., H.I., H.L.); and Center for Microbial Biotechnology, Department of Systems Biology, building 221, Søltofts Plads, Technical University of Denmark, DK-2800 Kgs. Lyngby, Denmark (I.S.)

Abstract

Analysis of aluminum hydroxide based vaccines is difficult after antigen adsorption. Adsorbed protein is often assessed by measuring residual unadsorbed protein for quality control. A new method for the direct determination of adsorbed protein concentration in suspension using near-infrared (NIR) transmittance spectroscopy is proposed here. A simple adsorption system using albumin from bovine serum (BSA) and aluminum hydroxide as a model system is employed. The results show that the NIR absorbance at 700–1300 nm is correlated to the adsorbed BSA concentration, measured by the ultraviolet (UV) method, using the partial least square regression (PLSR) method to construct a calibration model. The linear concentration range of adsorbed BSA is from 0 to 1.75 mg/mL by using 10 mm path length cuvettes. The influence of the sedimentation in suspension, different buffers, and different aluminum hydroxide batches was investigated in this study. It shows that the batch variation is the main influence factor of this method, while the buffer variation has no influence. However, the pretreatment of spectral data by subtracting spectra of BSA blank control (aluminum hydroxide without BSA) can significantly reduce the batch influence, and the NIR predicted results show good agreement with the reference values. The NIR method might be the only direct method for the determination of adsorbed protein concentration in suspension so far. It is a nondestructive method, and it has great advantage for use in vaccine production as a method for quality control and quality assurance.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3