Real-Time Fourier Transform-Infrared Analysis of Carbon Monoxide and Nitric Oxide in Sidestream Cigarette Smoke

Author:

Thompson Bruce T.1,Mizaikoff Boris1

Affiliation:

1. Brown & Williamson Tobacco Corp., P.O. Box 1056, Macon, Georgia 31202-1056 (B.T.T.); and Georgia Institute of Technology, School of Chemistry and Biochemistry, Atlanta, Georgia 30332 (B.T.T., B.M.)

Abstract

Fourier transform infrared (FT-IR) spectroscopy was compared directly to independent standard analytical techniques for the routine measurement of carbon monoxide (CO) and nitric oxide (NO) yields from cigarette sidestream smoke. The FT-IR instrument was configured in-line with a nondispersive infrared (NDIR) analyzer for CO analysis and a chemiluminescence (CL) analyzer for NO analysis to monitor the sidestream smoke from a single port of a linear smoking machine. A cold trap was inserted prior to the FT-IR to minimize the levels of vapor phase interferents, such as water. Univariate and multivariate regression analysis were evaluated for the prediction of cigarette yield from time-resolved spectral data at 1, 2, 4 and 8 cm−1 spectral resolution. Regressions were developed using three different spectral ranges including unique rotation-vibration lines, the R-branch, and the entire absorption band. As per standard methods, yields were calculated from the concentration traces generated during the smoke runs for five different cigarettes spanning the expected range of mainstream total particulate matter deliveries. The FT-IR traces for the smoke runs revealed improved temporal resolution yielding analytical information from smoke generated in between puffs. The performance between the validation methods and the FT-IR calibrations was statistically compared. In general, for the determination of CO, the FT-IR calibrations underestimated the yield measured by NDIR by less than 10%. For the NO measurement, the univariate FT-IR calibrations overestimated the NO yield measured by the CL analyzer, whereas the partial least squares (PLS) calibrations showed good agreement. PLS calibrations were developed for both analytes providing no significant difference when compared to the respective standard analytical techniques. Results for sidestream CO and NO yields for Kentucky reference cigarette 1R4F utilizing 8 cm−1 calibrations compared favorably to values reported elsewhere in the literature. Hence, calibration of the FT-IR system at 8 cm−1 spectral resolution clearly revealed the potential of this method, providing enhanced temporal resolution, simultaneous determination of several smoke components, and reduced complexity of the experimental setup in contrast to the standard techniques.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3