Practical Calibration Correction Method for the Maintenance of an On-Line Near-Infrared Monitoring System for Molten Polymers

Author:

Watari Masahiro1,Ozaki Yukihiro1

Affiliation:

1. Environmental and Analytical Products Business Division, Yokogawa Electric Corporation, Musashino 180-8750, Japan (M.W.); and Department of Chemistry and Research Center for Near-Infrared Spectroscopy, School of Science and Technology, Kwansei-Gakuin University, Sanda 669-1337, Japan (M.W., Y.O.)

Abstract

The present study has investigated a practical calibration correction method for an on-line monitoring system for molten polymers using a near-infrared (NIR) spectrometer. A partial least squares (PLS) calibration model for the ethylene (C2) content in melt polypropylene (PP) was developed for the investigation of changes in the performance of the on-line system before and after maintenance necessitated by the relocation. The predicted values for the C2 content from the spectra measured after maintenance by using the calibration model developed from the spectra collected before maintenance showed that there were some differences between the spectra obtained by the NIR spectrometer system before and after maintenance. The loadings from factor analysis suggested that the main cause for the differences in the system performance before and after maintenance was wavenumber shifts in the NIR spectra of PP in the melt state. Six popular standardization or calibration transfer methods (direct standardization (DS), piecewise direct standardization (PDS), additive correction (AD), multiplicative correction (MP), slope and bias (SB), and difference spectrum with interpolation (DSI)) were evaluated for the calibration correction of the on-line NIR monitoring system. However, the results of the evaluation showed that these standardization methods need more than two samples to obtain the high accuracy for the nonlinearity contained in the spectra set. From the standpoint of practical calibration in a real plant, the acceptable number of samples for the calibration is one or two. Moreover, recalibration using transferred spectra is not preferable because of the traceability for a calibration model. As a practical solution for a calibration correction in a real plant, a method considering wavenumber shift and path-length correction has been proposed in this study. The predicted results for the C2 content in the melt-state PP from the spectra measured after maintenance by using the proposed method have shown that the proposed method is useful for calibration correction in a real plant in spite of using only one sample.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Reference45 articles.

1. A Review of Process near Infrared Spectroscopy: 1980–1994

2. Siesler H. W., in Near-Infrared Spectroscopy-Principles, Instruments, Applications, Siesler H. W., Ozaki Y., Kawata S. and Heise H. M, Eds. (Wiley-VCH, Weinheim, 2002), p. 247.

3. Ozaki Y. and Amari T, in Spectroscopy in Process Analysis, Chalmers J. M. Ed. (Sheffield Academic Press, New York, 2000), p. 53.

4. Tate J. D., Chauvel P., Guenard R. D. and Harner R, Handbook of Vibrational Spectroscopy, Chalmers J. M. and Griffiths P. R, Eds. (John Wiley and Sons, Chichester, 2002), Vol. 4, p. 2737.

5. Kemeny G. J., in Handbook of Near-Infrared Analysis, Burns D. A. and Ciurczak E. W, Eds. (Marcel Dekker, New York, 2001), p. 729.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3