Picosecond Time-Resolved Raman Spectroscopy of Solids: Capabilities and Limitations for Fluorescence Rejection and the Influence of Diffuse Reflectance

Author:

Everall Neil1,Hahn Thomas1,Matousek Pavel1,Parker Anthony W.1,Towrie Michael1

Affiliation:

1. ICI PLC, Wilton Research Centre, Wilton, Redcar, Cleveland, TS10 4RF, UK (N.E.); National Starch and Chemical, 10 Finderne Avenue, Bridgewater, New Jersey (T.H.); and Central Laser Facility, CLRC Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire, OX1 0QX, UK (P.M., A.W.P., and M.T.)

Abstract

It has been known for many years that it should be possible to discriminate between Raman and fluorescence phenomena on the basis of their differing temporal responses. However, it is only relatively recently that optical technology has advanced sufficiently to achieve the necessary combination of high repetition rate and picosecond laser pulses, coupled with “gateable” multichannel detectors with matched repetition rates and short on-times. Both electronic and optical gating technologies have been shown to significantly improve the Raman spectra of highly fluorescent solutions. However, the performance of such systems with solid materials has not been reported in detail. To partially redress this imbalance, this article describes the ps-time-resolved Raman spectroscopy of solid films and powders. Excellent temporal resolution and fluorescence rejection was obtained with homogeneous films, but with powders, multiple scattering has the potential to significantly blur the time resolution. For example, after incidence of a 1-ps pulse on a powdered sample of trans-stilbene, the Rayleigh signal was spread over 100 ps in time and the Raman signal persisted for more than 300 ps. Simple models are presented that predict these temporal responses on the assumption that photons randomly “diffuse” through the powder, scattering at particle boundaries and sometimes reemerging to be detected at a later time. These dynamics imply that fluorescence rejection with bulk powders might be less effective than with homogeneous solids as the broadened Raman signal would be incompletely captured within the short detector “on” period. The fluorescence would be rejected, but so would the Raman signal (to some extent), giving a poor signal-to-noise ratio. This long-term signal persistence could also complicate the interpretation of pump-probe spectroscopy studies. However, further work is needed to assess the practical implications of these findings.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3