Analysis of Crystals Leading to Joint Arthropathies by Raman Spectroscopy: Comparison with Compensated Polarized Imaging

Author:

Cheng Xingguo1,Haggins Donard G.1,York Russel H.1,Yeni Yener N.1,Akkus Ozan1

Affiliation:

1. Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907 (X.C., O.A.); Department of Rheumatology, Henry Ford Hospital, 24555 Haig, Taylor, Michigan 48180 (D.G.H.); Beale Institute, 4333 W Joe Hwy #1, Lansing, Michigan 48917 (R.H.Y.); and Bone and Joint Center, Department of Orthopaedics and Rehabilitation, Henry Ford Hospital, 2799 West Grand Boulevard, Detroit, Michigan 48202 (Y.N.Y.)

Abstract

The current study assessed the feasibility of the application of Raman spectroscopy toward the diagnosis of gout and pseudogout. First, the lowest concentrations of monosodium urate monohydrate (MSUM) and calcium pyrophosphate dihydrate (CPPD) crystals detectable by Raman spectroscopy were investigated by mixing known amounts of synthetic crystals with synovial fluid in the concentration range of 1 to 100 μg/mL. Second, a digestion protocol was developed for clinical samples to improve crystal extraction. The ensuing centrifugation of the digest congregated crystals at a well-defined point and allowed for point-and-shoot Raman analysis without having to conduct an extensive search for individual crystals. Finally, synovial fluid samples obtained from patients ( n = 35) were cross-analyzed by polarized light microscopy (PLM) and the Raman method to compare and contrast the diagnoses of the two methods. It was found that Raman spectroscopy can detect MSUM and CPPD crystals with good sensitivity and specificity at concentrations as low as 5 μg/mL and 2.5 μg/mL, respectively, using the current method. This detection limit of Raman analysis is lower than that reported for PLM. Raman and PLM diagnoses of clinical samples agreed in 32 out of 35 samples in the entire sample pool. However, the rate of disagreement between PLM-based and Raman-based diagnoses was noteworthy within the subset of diseased samples (3 out of 10), indicating that PLM has limitations and that the confirmation by a secondary method is essential for a reliable outcome. The proposed protocol of sample preparation and Raman analysis ascribes baseline feasibility to the diagnosis of gout and pseudogout by Raman spectroscopy, thus justifying further studies using a larger clinical sample set for obtaining sensitivity and specificity.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3