Multiple Filtering Strategy for the Automated Detection of Ethanol by Passive Fourier Transform Infrared Spectrometry

Author:

Idwasi Patrick O.1,Small Gary W.1,Combs Roger J.1,Knapp Robert B.1,Kroutil Robert T.1

Affiliation:

1. Center for Intelligent Chemical Instrumentation, Department of Chemistry and Biochemistry, Ohio University, Athens, Ohio 45701-2979 (P.O.I., G.W.S.); and U.S. Army, SBCCOM, Edgewood Chemical Biological Center, Aberdeen Proving Ground, Maryland 21010-5424 (R.J.C., R.B.K., R.T.K.)

Abstract

Digital filtering methods are evaluated for use in the automated detection of ethanol from passive Fourier transform infrared (FT-IR) data collected during laboratory and open-air remote sensing experiments. In applications in which analyte signals are overwhelmed by the overlapping signals of an interference, the use of multiple digital filters is observed to improve the sensitivity of the analyte detection. The detection strategy is based on the application of bandpass digital filters to short segments of the interferogram data collected by the FT-IR spectrometer. To implement the automated detection of a target analyte, the filtered interferogram segments are supplied as input to piecewise linear discriminant analysis. Through the use of a set of training data, discriminants are computed that can subsequently be applied to detect the presence of the analyte in an automated manner. This research focuses on the detection of ethanol vapor in the presence of an ammonia interference. A two-filter detection strategy based on the use of separate ethanol and ammonia filters is compared to an approach based on a single ethanol filter. Bandpass parameters of the digital filters and the interferogram segment location are optimized through the use of laboratory data in which ethanol and ammonia vapors are generated in a gas cell and viewed against various infrared background radiances. The filter and segment parameters obtained through this optimization are subsequently tested with field remote sensing data collected when the spectrometer is allowed to view ethanol and ammonia plumes generated from a heated stack. The two-filter strategy is found to outperform the single-filter approach with both the laboratory and field data in situations in which the ammonia interference dominates the ethanol signature.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3