Combining Self-Modeling Curve Resolution Methods and Partial Least Squares to Develop a Quantitative Reaction Monitoring Method with Minimal Reference Data

Author:

Pedge Nicholas I.1,Walmsley Anthony D.1

Affiliation:

1. Process Research and Development Department, AstraZeneca R&D Charnwood, Loughborough, Leicestershire, LE11 5RH, United Kingdom (N.I.P.); and Department of Chemistry, The University of Hull, Cottingham Road, Hull, HU6 7RX, United Kingdom (A.D.W.)

Abstract

An example of combining self-modeling curve resolution (SMCR) methods and partial least squares (PLS) to construct a quantitative model using minimal reference data is presented. The objective was to construct a quantitative calibration model to allow real-time in situ ultraviolet–attenuated total reflection (UV/ATR) measurements to determine the end-point during a chlorination reaction. Time restrictions for development combined with difficult reaction sampling conditions required the method to be developed using only a few key reference measurements. Utilizing evolving factor analysis (EFA) and the orthogonal projection approach (OPA), initial estimates of the concentration and spectral profiles for the intermediate and product were obtained. Further optimization by multivariate curve resolution–alternating least squares (MCR-ALS) led to refined estimates of the concentration profiles. A PLS2 model was then constructed using the calculated concentration profiles and the preprocessed UV spectra. Using a standard PLS model compatible with the spectrometer's standard process software facilitated real-time predictions for new batches. This method was applied to five 45 liter batches in a large-scale laboratory facility. The method successfully predicted the product concentration of batch 1 but exhibited larger prediction error for subsequent batches. The largest prediction error was attained during batch 3, for which a final concentration of 0.22 mole·L−1 was predicted, while the true measured value was 0.271 mole·L−1 (an error of 18.8%). However, the qualitative real-time profiles proved to be extremely useful as they allowed the end-point to be determined without sampling or performing off-line analysis. Furthermore, the concentration profile of the intermediate species, which could not be observed by the off-line method, could also be observed in real-time and gave further confidence that the process was approaching the end-point. Another benefit of real-time reaction profiles was encountered during the manufacture when the formation of product in batch 3 appeared to be progressing slower than was observed in previous batches. This prompted a check of the batch temperature and it was found to be 10 °C lower than the required set-point. The temperature was corrected and the batch successfully reached completion in the expected time.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3