Performance Analysis of an Integrated Process Raman Analyzer Using a Multiplexed Transmission Holographic Grating, CCD Detection, and Confocal Fiber-Optic Sampling

Author:

Everall Neil1,Owen Harry1,Slater Joe1

Affiliation:

1. ICI plc, Wilton Research Centre, P.O. Box 90, Wilton, Middlesbrough, Cleveland, TS90 8JE, U.K. (N.E.); and Kaiser Optical Systems Inc., Ann Arbor, Michigan, U.S.A. (H.O., J.S.)

Abstract

The performance of an integrated turn-key on-line Raman spectrometer based upon a multiplexed transmission holographic grating, holographic laser rejection filters, and a charge-coupled-device (CCD) detector is described and compared with a laboratory-based research-grade FT-Raman spectrometer. Data for the dispersive system were acquired with a noncontacting, confocal dual-fiber probe of up to 100-m length, with Raman shifts down to 50 cm−1 and no apparent fiber background features. Despite the fact that the FT-Raman system was directly coupled to the sample (i.e., not through fibers), the sensitivity of the dispersive system was almost three orders of magnitude greater for equivalent incident laser powers and accumulation times. The potential for performing multivariate calibrations with the dispersive equipment was also investigated. With samples of known density, it was possible to produce a partial least-squares calibration for poly(thylene terephthalate) (PET) density with a precision of 0.002 g cm−3, with the use of a two-factor model. This precision compared favorably with previous calibrations using FT-Raman data. The effect of changing the f-number of the collection optics of the fiber probe head (to allow variation in the working distance) was also examined. It was found that, for transparent samples, the f-number could be changed by a factor of three without greatly affecting the Raman signal intensity, whereas for an opaque solid increasing the f-number greatly reduced the detected intensity. The reasons for this difference are discussed

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3