Time-Domain (Interferogram) and Frequency-Domain (Absorption-Mode and Magnitude-Mode) Noise and Precision in Fourier Transform Spectrometry

Author:

Liang Zhenmin1,Marshall Alan G.1

Affiliation:

1. Department of Chemistry (Z.L., A.G.M.) and Department of Biochemistry (A.G.M.), The Ohio State University, 120 West 18th Avenue, Columbus, Ohio 43210

Abstract

It is desirable to be able to predict the precision of a repeated measurement, based on the result of a single measurement and knowledge of the noise level in the original (time-domain) data. We have previously shown that precision in determination of time-domain signal parameters (initial magnitude, frequency, and exponential damping constant for a noisy exponentially damped sinusoidal signal) from least-squares fit to a frequency-domain FFT spectrum is directly proportional to frequency-domain peak height-to-noise ratio and to the square root of the number of data points per peak width, with a proportionality constant which depends on the spectral type (absorption mode, magnitude mode) and peak shape (e.g., Lorentzian, Gaussian, etc.). In this paper, we show that precision in determination of those same parameters by least-squares fit to the time-domain signal itself is similarly related to time-domain initial amplitude-to-noise ratio and the square root of the number of data points per damping period. In addition, we show that although magnitude-mode spectral noise is well described by a Rayleigh distribution in the signal-free baseline segments of the spectrum, noise in the vicinity of a magnitude-mode spectral peak is more accurately described by a normal (Gaussian) distribution. We then proceed to show that determination of spectral parameters from a time-domain data set is more precise by a factor of √2 than estimates based on the FT absorption-mode spectrum. We further show that padding of the N-point time-domain data set by another N zeroes before FFT improves frequency-domain absorption-mode precision by the same √2 factor. Additional zero-filling does not improve spectral precision. Zero-filling has no effect on precision of spectral parameters determined from time-domain data, and variable effects on parameters determined from fits to magnitude-mode spectra. The above theoretical predictions are supported by analysis of simulated noisy data.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3