Determination of Thallium, Manganese, and Lead in Food and Agricultural Standard Reference Materials by Electrothermal Atomizer Laser-Excited Atomic Fluorescence and Atomic Absorption Spectrometry with Slurry Sampling

Author:

Butcher David J.1,Irwin Richard L.1,Takahashi Junichi1,Su Guizhen1,Wei Guor-Tzo1,Michel Robert G.1

Affiliation:

1. Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269

Abstract

Electrothermal atomizer laser-excited atomic fluorescence spectrometry (ETA LEAFS) and electrothermal atomic absorption spectrometry (ETA AAS) have been compared for the determination of three elements in National Institute of Standards and Technology food and agricultural standard reference materials with dissolved and slurried samples. Advantages of slurry sampling include reduced sample preparation and a reduced risk of contamination. ETA LEAFS is an extremely sensitive technique, with detection limits one to four orders of magnitude more sensitive than ETA AAS. Using the front-surface illumination approach, this paper reports the first application of a modern, unmodified graphite tube furnace for the determination of manganese, thallium, and lead in biological materials by ETA LEAFS. Thallium was determined by ETA LEAFS at levels one to two orders of magnitude below the ETA AAS detection limit. The determinations done by ETA LEAFS with the use of either dissolved or slurry sampling agreed well with the certified values, with typical analytical RSDs between 3 and 10%. These precisions were similar to the precisions of the ETA AAS measurements. For ETA AAS, the sizes of the background signals reported in the literature are often about the same order of magnitude as the analytical signal. In this work, the sizes of the background signals for ETA LEAFS were shown to be negligible relative to the fluorescence signals for most samples investigated. The relatively small size for the ETA LEAFS background signals, when compared to ETA AAS background signals, indicates that background correction errors are less likely, and that stringent specifications might be unnecessary for ETA LEAFS background correction instrumentation.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Reference52 articles.

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3