Use of CLS to Understand PLS IR Calibration for Trace Detection of Organic Molecules in Water

Author:

Haaland David M.1,Han Ling1,Niemczyk Thomas M.1

Affiliation:

1. Sandia National Laboratories, Albuquerque, New Mexico 87185-0342 (D.M.H.); and Department of Chemistry, University of New Mexico, Albuquerque, New Mexico 87131 (L.H., T.M.N.)

Abstract

Partial least-squares (PLS) and principal component regression (PCR) methods applied to spectral data can generally provide excellent quantitative analysis precision, but extraction of qualitative spectral interpretation from the models can be more difficult. For example, we have achieved sensitivity in the parts-per-million range for polar organic compounds in aqueous solutions using infrared (IR) spectroscopy and modified sol-gel-coated ATR sensors. The interpretation of PLS or PCR loading vectors obtained from calibrations involving orthogonally designed solutions of acetone and isopropanol in water yields a misleading understanding of the mechanism for the IR detection of isopropanol on these sensors. Examination of the loading vectors from PLS or PCR or the first weight-loading vector from the PLS model would suggest that the spectral calibration is based largely on the interaction of the isopropanol with the surface modifier of the sol-gel coating. However, a classical least-squares (CLS) analysis of the data shows clearly that this interaction is not a significant source of the spectral calibration, but rather the calibration is primarily due to the spectroscopic signal of the isopropanol analyte. In this case, the misleading qualitative interpretation of the PLS and PCR models is the result of the spectral variation being dominated by the effects of spectrometer drift. CLS can overcome this problem if a parameter is included in the CLS calibration that adequately represents the drift. In the example presented here, time of spectral data collection is an appropriate drift-related parameter that can be added to the CLS calibration concentration model in order to provide the qualitative information needed to correctly interpret the spectral data. Other methods to include the effects of spectrometer drift in the CLS model are also presented.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3