Infrared Intensities of Liquids III: The Photometric Accuracy of FT-IR Transmission Spectra of C5H10, CH3NO2, CH2Cl2, C6H6, C6H5·CH3, and C6H5Cl in the Liquid State at 25°C in 11- to 500-μm Cells

Author:

Bertie John E.1,Jones R. Norman1,Behnam Victor1

Affiliation:

1. Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada

Abstract

This paper completes the report of our FT-IR measurements of transmission spectra of organic liquids. These measurements were undertaken in order to estimate the photometric accuracy of our FT-IR spectrometer for transmission spectra by comparing the results with those measured previously [Applied Spectroscopy 34, 657 (1980)] by a calibrated dispersive spectrometer. We have studied 97 bands of chlorobenzene, toluene, and dichloromethane, in 500-μm cells and 54 bands of benzene, chlorobenzene, toluene, cyclopentane, and dichloromethane, in cells 11 to 53 μm thick. The average value of the imaginary refractive index at the band peak, kmax, is reported for each band and compared with the calibrated value. When averaged over the 184 bands that are reported in this work and our earlier paper [Applied Spectroscopy 39, 401 (1985)], our measurements agree with the calibrated values to about 3% of kmax, and have a 90% confidence limit of about 0.7 to 1% of kmax, The calibrated values themselves have an estimated error of about 6%, so to obtain better knowledge of the accuracy of our measurements we need better standards and we need measurements to be made on other FT-IR instruments. We plan to publish simplified procedures that will encourage others to make such measurements. Our 90% confidence limit includes effects due to the use of different cells, daily realignment of the fixed mirror of the interferometer, realignment of the optics of the detector and sample compartments, change of beamsplitter, and a day-to-day variation of uncertain origin, in addition to the error sources that always contribute to typical analytical precision. Our data do not show these additional error sources to be systematic, so it is appropriate to include their effect in the evaluation of the confidence limit. We believe the main source of error to be the effect of the infrared cell on the path of the light beam through the instrument. The day-to-day variation of uncertain origin is thought to be due to very small changes in the beam path through the instrument, which in turn cause the effect of the infrared cell on the beam to vary.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3