Investigation of Dose Calculation Accuracy of Eclipse Treatment Planning System in the Presence of Metal Hip Prosthesis with Thermoluminescence Dosimeters

Author:

Gül Osman Vefa1ORCID,Başaran Hamit2ORCID,Yıldırım Ahmet2ORCID,İnan Gökçen2ORCID

Affiliation:

1. SELÇUK ÜNİVERSİTESİ

2. SELCUK UNIVERSITY

Abstract

Aim: This study investigated the dose calculation accuracy of different treatment planning algorithms used in radiotherapy patients with hip prostheses. Method: The current research produced a tissue-equivalent cylindrical phantom that imitates a leg using a 3D printer. Co-Cr-Mo alloy and Ti-6AI-4V alloy prostheses were placed in the centre of the phantom, respectively. Both prostheses' dose measurements were taken with thermoluminescent dosimeters (TLD) at 92 points. The dose calculation accuracy of the Analytical Anisotropic Algorithm (AAA) and Pencil Beam Convolution (PBC) algorithms, widely used in radiotherapy, were compared with the measurement results. Results: Since the Co-Cr-Mo hip prosthesis has a high density, the number of backscattered photons around it was higher than the Ti-6AI-4V hip prosthesis. The average surface dose of the Co-Cr-Mo alloy was 364.05 cGy, while the average surface dose of the Ti-6AI-4V alloy was 347.79 cGy. Conclusion: It was observed that the dose estimation abilities of the AAA and PBC algorithms decreased as the density of the hip replacement increased. In addition, the AAA algorithm predicted the surface dose in the phantom better than the PBC algorithm.

Funder

Selcuk University

Publisher

Istanbul Gelisim University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3