External validation of a multivariate model for predicting the risk of death in patients with chronic heart failure and an implantable cardioverter – defibrillator

Author:

Lebedeva N. B.1ORCID,Parfenov P. G.1ORCID,Egle A. P.1ORCID,Ivanov V. I.2ORCID,Galintsev Yu. V.2ORCID,Kashtalap V. V.1ORCID,Barbarash O. L.1ORCID

Affiliation:

1. Research Institute for Complex Problems of Cardiovascular Diseases

2. Kemerovo State Medical University

Abstract

Aim. To perform external validation of a multivariate model for predicting the risk of death in patients with an implantable cardioverter – defibrillator (ICD) in an independent sample. Materials and methods. The group for model development included 260 patients from the Implantable Cardioverter – Defibrillator Patient Registry who had an ICD implanted between 2015 and 2019. External validation of the model was carried out in an independent, prospective, observational cohort study of patients from the same registry, in whom an ICD was implanted between 2020 and 2021, a total of 94 patients, median age 66 (52;73) years, 73 (77.6%) men, 21 (22.4%) women. In 89 (94.7%) patients, an ICD was implanted for primary prevention of sudden cardiac death. Following a telephone survey and examination of medical records from hospital and clinic databases, data on the vital status (alive / dead) and causes of death were obtained during a 2.5-year follow-up. The actual and predicted mortality from the estimated multivariate model were compared. Results. During the follow-up, a total of 26 (27.7%) patients died in the external validation group, which was comparable to the development group (p > 0.05). In the group of deceased, 15 (57.7%) people developed acute decompensated heart failure, 4 (14.8%) had myocardial infarction, 6 (23.1%) had pneumonia caused by a new coronavirus infection, and one (3.8%) patient died due to an infectious complication. The diagnostic accuracy of the multivariate model for predicting the risk of death in patients with ICD in an independent sample was sufficient (the area under the curve (AUC) of the created model was 0.8). The sensitivity of the model was 76.2%, specificity – 76.1%. Previously, in the development cohort, AUC of the created model was 0.8, the sensitivity of the model was 75.7%, and the specificity was 80%. Model significance did not differ significantly between the development and external validation groups (p = 0.102, McNeil test).Conclusion. The multivariate prediction model has sufficient statistical power to predict the risk of long-term death after ICD implantation, which was externally validated.

Publisher

Siberian State Medical University

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3