Abstract

Background and Purpose Previous research has indicated that not all ultrasound transducers heat at equal rates; however, the cause of this disparity is unclear. Variability in spatial average intensity (SAI) has been implicated in this disparity at 3 MHz. This variability has not been explored at 1 MHz. Methods Sixty-six 5-cm2 ultrasound transducers were purchased from 6 different manufacturers. Transducers were calibrated and assessed for effective radiating area (ERA), total output power, and SAI using standardized measurement techniques. Results Total output power values fell within US Food and Drug Administration guidelines, but there were large variations in ERA. The resulting SAI values showed large deviations (−43% to +61%) from the digitally displayed value. Intra-manufacturer SAI values varied up to 53%. Discussion and Conclusion Spatial average intensity can vary largely from the values displayed on these ultrasound generators; in a calibrated cohort, this difference is primarily attributable to differences in measured ERA. Patterns of SAI variability within the manufacturer at 1 MHz do not follow previous reports of variability at 3 MHz.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

Reference32 articles.

1. Heating produced by ultrasound in bone and soft tissue;Lehmann;Arch Phys Med Rehabil,1967

2. Therapeutic temperature distribution produced by ultrasound as modified by dosage and volume of tissue exposed;Lehmann;Arch Phys Med Rehabil,1967

3. A review of therapeutic ultrasound: effectiveness studies;Robertson;Phys Ther,2001

4. Effects of two ultrasound devices and angles of application on temperature of the tissue phantom;Kimura;J Orthop Sports Phys Ther,1998

5. Rate of temperature increase in human muscle during 1 MHz and 3 MHz continuous ultrasound;Draper;J Orthop Sports Phys Ther,1995