Abstract

Background: With the increasing incidence of Alzheimer disease (AD), determining the validity and reliability of outcome measures for people with this disease is necessary.Objective: The goals of this study were to assess test-retest reliability of data for the Timed “Up & Go” Test (TUG), the Six-Minute Walk Test (6MWT), and gait speed and to calculate minimal detectable change (MDC) scores for each outcome measure. Performance differences between groups with mild to moderate AD and moderately severe to severe AD (as determined by the Functional Assessment Staging [FAST] scale) were studied.Design: This was a prospective, nonexperimental, descriptive methodological study.Methods: Background data collected for 51 people with AD included: use of an assistive device, Mini-Mental Status Examination scores, and FAST scale scores. Each participant engaged in 2 test sessions, separated by a 30- to 60-minute rest period, which included 2 TUG trials, 1 6MWT trial, and 2 gait speed trials using a computerized gait assessment system. A specific cuing protocol was followed to achieve optimal performance during test sessions.Results: Test-retest reliability values for the TUG, the 6MWT, and gait speed were high for all participants together and for the mild to moderate AD and moderately severe to severe AD groups separately (intraclass correlation coefficients ≥.973); however, individual variability of performance also was high. Calculated MDC scores at the 90% confidence interval were: TUG=4.09 seconds, 6MWT=33.5 m (110 ft), and gait speed=9.4 cm/s. The 2 groups were significantly different in performance of clinical tests, with the participants who were more cognitively impaired being more physically and functionally impaired.Limitations: A single researcher for data collection limited sample numbers and prohibited blinding to dementia level.Conclusions: The TUG, the 6MWT, and gait speed are reliable outcome measures for use with people with AD, recognizing that individual variability of performance is high. Minimal detectable change scores at the 90% confidence interval can be used to assess change in performance over time and the impact of treatment.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3