Modified Total-Body Recumbent Stepper Exercise Test for Assessing Peak Oxygen Consumption in People With Chronic Stroke

Author:

Billinger Sandra A1,Tseng Benjamin Y2,Kluding Patricia M3

Affiliation:

1. SA Billinger, PT, MSPT, FAHA, is a PhD candidate and Clinical Instructor, Metabolic, Strength, and Energy Lab, Department of Physical Therapy and Rehabilitation Science, University of Kansas Medical Center, 3901 Rainbow Blvd, Mail Stop 2002; Kansas City, KS 66160 (USA)

2. BY Tseng, MS, is a PhD candidate and Graduate Research Assistant, Department of Physical Therapy and Rehabilitation Science, University of Kansas Medical Center

3. PM Kluding, PT, PhD, is Assistant Professor, Department of Physical Therapy and Rehabilitation Science, University of Kansas Medical Center

Abstract

Background Assessment of peak oxygen consumption (V̇o2peak) using traditional modes of testing such as treadmill or cycle ergometer can be difficult in individuals with stroke due to balance deficits, gait impairments, or decreased coordination. Objective The purpose of this study was to quantitatively assess the validity and feasibility of a modified exercise test using a total-body recumbent stepper (mTBRS-XT) in individuals after stroke. Design A within-subject design, with a sample of convenience, was used. Participants Eleven participants (7 male, 4 female) with a mean of 40.1 months (SD=32.7) after stroke, a mean age of 60.9 years (SD=12.0), and mild to severe lower-extremity Fugl-Myer test scores (range=13–34) completed the study. Methods Participants performed 2 maximal-effort graded exercise tests on separate days using the mTBRS-XT and a cycle ergometer exercise protocol to assess cardiorespiratory fitness. Measurements of V̇o2peak and peak heart rate (peak HR) were obtained during both tests. Results A strong relationship existed between the mTBRS-XT and the cycle ergometer exercise test for V̇o2peak and peak HR (r=.91 and .89, respectively). Mean V̇o2peak was significantly higher for the mTBRS-XT (16.6 mL×kg−1×min−1[SD=4.5]) compared with the cycle ergometer exercise protocol (15.4 mL×kg−1×min−1 [SD=4.5]). All participants performed the mTBRS-XT. One individual with severe stroke was unable to pedal the cycle ergometer. No significant adverse events occurred. Conclusion The mTBRS-XT may be a safe, feasible, and valid exercise test to obtain measurements of V̇o2peak in people with stroke. Health care professionals may use the mTBRS-XT to prescribe aerobic exercise based on V̇o2peak values for individuals with mild to severe deficits after stroke.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3