Analysis of electrotherapy in patients with implantable cardioverter-defibrillator for primary prevention of sudden cardiac death according to remote monitoring data

Author:

Lebedeva V. K.1ORCID,Levinova O. E.1ORCID

Affiliation:

1. V.A. Almazov National Medical Research Center of Ministry of Health of the Russian Federation

Abstract

Aim: To determine the factors associated with development of justified and inappropriate implantable cardioverter-defibrillator (ICD) activations in patients at high risk of sudden cardiac death based on the remote monitoring systemMaterial and Methods. We analyzed remote monitoring data from 2014 to 2022 in 132 patients with ICD for primary prevention of sudden cardiac death (SCD). Patients were divided into 2 groups 1 – patients with persistent paroxysmal tachyarrhythmias; 2 – patients without persistent paroxysms of ventricular tachycardia (VT) / ventricular fibrillation (VF). In case of inappropriate shocks, the causes and possible predictors of their development were analyzed.Results. Of 132 patients, 62 (46.9%) patients appeared to have persistent VT/VF. It was found that the probability of detecting persistent paroxysms of VT/VF decreased with a history of revascularization (p = 0.030) and increased in the absence of amiodarone therapy (p = 0.012), with increasing age (p = 0.035), with decreasing left ventricular ejection fraction (LVEF) less than 35% (p = 0.016). 71 arrhythmic episodes (17.9%) in 27 (20.4%) patients were considered as false detection of tachyarrhythmias. Analyzing the causes of inappropriate electrotherapy, different types of supraventricular tachyarrhythmias in the zone of VT detection (85.9%), including atrial fibrillation (25.4%), in smaller percentage of cases there was discovered T-wave detection 4.2%, noise on the electrode – 2.8%, 7.1% – double counter due to the operation of the cardiac contractility modulation device. When analyzing factors associated with the development of false detection, reliable results were obtained with regard to the presence of a history of atrial fibrillation (p = 0.036), implanted single-chamber ICD (p = 0.028).Conclusion. The development of persistent ventricular tachyarrhythmias was noted in 47% of patients with ICD as a part of primary prevention of sudden cardiac death, and 20.4% had the development of inappropriate detection and electrotherapy. Predictors of their occurrence have been identified, which can be used as development of strategies for shock minimization.

Publisher

Cardiology Research Institute

Subject

Cardiology and Cardiovascular Medicine,Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,Medicine (miscellaneous),Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3